 BattMonitor_DB_Builder/src/com/database_util/DB_Pwrdev_Alarm.java |  180 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-
 1 files changed, 177 insertions(+), 3 deletions(-)

diff --git a/BattMonitor_DB_Builder/src/com/database_util/DB_Pwrdev_Alarm.java b/BattMonitor_DB_Builder/src/com/database_util/DB_Pwrdev_Alarm.java
index 7dcb34c..e1eeae9 100644
--- a/BattMonitor_DB_Builder/src/com/database_util/DB_Pwrdev_Alarm.java
+++ b/BattMonitor_DB_Builder/src/com/database_util/DB_Pwrdev_Alarm.java
@@ -320,6 +320,7 @@
 				"  `alarm_source` int(11) NOT NULL DEFAULT '0' COMMENT '告警数据来源[0-设备告警点位判断;1-当前阈值判断]'," + 
 				"  `alarm_name` varchar(255) NOT NULL DEFAULT '' COMMENT '当前告警描述'," + 
 				"  `alarm_type` int(11) NOT NULL DEFAULT '0' COMMENT '0-上下限有效  1-上限有效  2-下限有效'," + 
+				"  `alarm_en_node` int(4) NOT NULL DEFAULT '1' COMMENT '告警来源是点位时告警使能[0:不启用;1:启用]'," + 
 				"  PRIMARY KEY (`num`)" + 
 				") ENGINE=InnoDB DEFAULT CHARSET=utf8 COMMENT='山西电源告警参数表';";
 		Sql_Mysql sql = new Sql_Mysql(pool.getConn());
@@ -329,11 +330,25 @@
 				sql.sqlMysqlExecute(sql_str01);
 			}
 			sql.sqlMysqlExecute(sql_str02);
+			
+			//添加 alarm_en_node -- 告警来源是点位时告警使能[0:不启用;1:启用]
+			res = sql.sqlMysqlQuery("SELECT * FROM information_schema.columns"
+					+ " WHERE table_schema='db_pwrdev_alarm'"
+					+ " AND table_name='tb_pwrdev_alarm_param_forsx'"
+					+ " AND column_name='alarm_en_node'");
+			if(false == res.next()) {
+				sql.sqlMysqlExecute("ALTER TABLE " + Sql_Mysql.Pwrdev_Alarm_History_Table 
+						+ " ADD COLUMN `alarm_en_node` int(4) NOT NULL DEFAULT '1' COMMENT '告警来源是点位时告警使能[0:不启用;1:启用]';");
+			}
+			
+			
 			res = sql.sqlMysqlQuery("SELECT PowerDeviceId FROM " + Sql_Mysql.Pwrdev_Inf_Table);
 			StringBuffer buf_base = new StringBuffer("INSERT INTO " + Sql_Mysql.Pwrdev_Alarm_Param_ForSX_Table + "(PowerDeviceId,alm_id,alm_level,alarm_limitH,alarm_limitH_EN,alarm_limitL,alarm_limitL_EN,alarm_name,alarm_type) VALUES");
 			StringBuffer buf_body = new StringBuffer();
 			while(res.next()) {
 				int PowerDeviceId = res.getInt("PowerDeviceId");
+				
+				
 				
 				//交流A相过压告警
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_A_OverV_ID,SqlsUtils.Alarm_Level_Second,198,true, 135.4f,false,"交流A相过压告警",1,pool);
@@ -354,12 +369,83 @@
 				//交流C相缺相告警
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_C_Less_ID,SqlsUtils.Alarm_Level_Second,198,false, 110,true,"交流C相缺相告警",2,pool);
 				
-				//交流A相过流告警
+				
+				//交流停电告警		110010
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_PowerDown_ID,SqlsUtils.Alarm_Level_First,54,false, 49,true,"交流停电告警",2,pool);
+				//防雷器故障告警	110011
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_ThunderErr_ID,SqlsUtils.Alarm_Level_Second,54,false, 49,false,"防雷器故障告警",2,pool);
+				//直流电压过高告警	110012
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_DCout_OverV_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"直流电压过高告警",1,pool);
+				//直流电压过低告警	110013
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_DCout_UnderV_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"直流电压过低告警",2,pool);
+				//负载熔断告警		110014
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_LoaderFuse_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"负载熔断告警",2,pool);
+				//电池组1熔断告警		110015
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_BattGrp1Fuse_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"电池组1熔断告警",2,pool);
+				//电池组2熔断告警		110016
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_BattGrp2Fuse_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"电池组2熔断告警",2,pool);
+				//整流器1总故障告警		110017
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module1Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器1总故障告警",2,pool);
+				//整流器2总故障告警		110018
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module2Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器2总故障告警",2,pool);
+				//整流器3总故障告警		110019
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module3Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器3总故障告警",2,pool);
+				//整流器4总故障告警		110020
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module4Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器4总故障告警",2,pool);
+				//整流器5总故障告警		110021
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module5Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器5总故障告警",2,pool);
+				//整流器6总故障告警		110022
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module6Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器6总故障告警",2,pool);
+				//整流器7总故障告警		110023
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module7Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器7总故障告警",2,pool);
+				//整流器8总故障告警		110024
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module8Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器8总故障告警",2,pool);
+				//整流器9总故障告警		110025
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module9Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器9总故障告警",2,pool);
+				//整流器10总故障告警	110026
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module10Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器10总故障告警",2,pool);
+				//整流器11总故障告警	110027
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module11Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器11总故障告警",2,pool);
+				//整流器12总故障告警	110028
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module12Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器12总故障告警",2,pool);
+				//整流器13总故障告警	110029
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module13Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器13总故障告警",2,pool);
+				//整流器14总故障告警	110030
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module14Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器14总故障告警",2,pool);
+				//整流器15总故障告警	110031
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module15Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器15总故障告警",2,pool);
+				//整流器16总故障告警	110032
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Module16Err_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"整流器16总故障告警",2,pool);
+				//交流总故障告警	110033
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcAlarm_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"交流总故障告警",2,pool);
+				//直流总故障告警	110034
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_DcAlarm_ID,SqlsUtils.Alarm_Level_Second,54,true, 49,false,"直流总故障告警",2,pool);
+				
+				//交流A相过流告警		110035
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Acb1_OverCurrA_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流A相过流告警",1,pool);
-				//交流B相过流告警
+				//交流B相过流告警		110036
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Acb1_OverCurrB_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流B相过流告警",1,pool);
-				//交流C相过流告警
+				//交流C相过流告警		110037
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Acb1_OverCurrC_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流C相过流告警",1,pool);
+				
+				//监控器故障告警	110038
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_MonitorErr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"监控器故障告警",1,pool);
+				//直流过流告警		110039
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_DcOut_OverCurr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"直流过流告警",1,pool);
+				//开关柜总报警		110040
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_TolalAlarm_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"开关柜总报警",1,pool);
+				//电池组1电压低告警		110041
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt1_VolLow_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组1电压低告警",1,pool);
+				//电池组2电压低告警		110042
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt2_VolLow_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组2电压低告警",1,pool);
+				//电池组1下电告警		110043
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt1_Down_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组1下电告警",1,pool);
+				//电池组2下电告警		110044
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt2_Down_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组2下电告警",1,pool);
+				//电池组1充电过流告警	110045
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt1_OverChgCurr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组1充电过流告警",1,pool);
+				//电池组2充电过流告警	110046
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Batt2_OverChgCurr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电池组2充电过流告警",1,pool);
 				
 				
 				//整流器1过压告警
@@ -460,8 +546,96 @@
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod15_OverCurr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器15过流告警",1,pool);
 				//整流器16过流告警
 				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod16_OverCurr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器16过流告警",1,pool);
+				
+				//整流器1交流异常告警			110095
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod1_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器1交流异常告警",1,pool);
+				//整流器2交流异常告警			110096
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod2_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器2交流异常告警",1,pool);
+				//整流器3交流异常告警			110097
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod3_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器3交流异常告警",1,pool);
+				//整流器4交流异常告警			110098
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod4_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器4交流异常告警",1,pool);
+				//整流器5交流异常告警			110099
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod5_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器5交流异常告警",1,pool);
+				//整流器6交流异常告警			110100
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod6_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器6交流异常告警",1,pool);
+				//整流器7交流异常告警			110101
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod7_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器7交流异常告警",1,pool);
+				//整流器8交流异常告警			110102
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod8_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器8交流异常告警",1,pool);
+				//整流器9交流异常告警			110103
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod9_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器9交流异常告警",1,pool);
+				//整流器10交流异常告警			110104
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod10_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器10交流异常告警",1,pool);
+				//整流器11交流异常告警			110105
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod11_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器11交流异常告警",1,pool);
+				//整流器12交流异常告警			110106
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod12_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器12交流异常告警",1,pool);
+				//整流器13交流异常告警			110107
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod13_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器13交流异常告警",1,pool);
+				//整流器14交流异常告警			110108
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod14_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器14交流异常告警",1,pool);
+				//整流器15交流异常告警			110109
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod15_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器15交流异常告警",1,pool);
+				//整流器16交流异常告警			110110
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_Mod16_AC_Err_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"整流器16交流异常告警",1,pool);
+				//交流输入1跳闸告警			110111
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_Trip_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流输入1跳闸告警",1,pool);
+				//交流输入2跳闸告警			110112
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn2_Trip_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流输入2跳闸告警",1,pool);
+				//交流输入1熔丝告警			110113
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_Fuse_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流输入1熔丝告警",1,pool);
+				//交流输入2熔丝告警			110114
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn2_Fuse_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流输入2熔丝告警",1,pool);
+				//交流输入1三相不平衡告警		110115
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_Unbalance_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"交流输入1三相不平衡告警",1,pool);
+				//交流输入2三相不平衡告警		110116
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn2_Unbalance_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"交流输入2三相不平衡告警",1,pool);
+				//交流输入1频率异常告警			110117
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn1_FreqErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"交流输入1频率异常告警",1,pool);
+				//交流输入2频率异常告警			110118
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_AcIn2_FreqErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"交流输入2频率异常告警",1,pool);
+				//协转通信故障告警			110119
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_ACDC_CPSS_CommErr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"协转通信故障告警",1,pool);
 
 				
+
+				//1+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+				//电源通信故障告警			110120
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_PWRDEV_CommErr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"电源通信故障告警",1,pool);
+				//交流输入1停电告警			110121
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_User_AcIn1_PowerDown_ID,SqlsUtils.Alarm_Level_First,100,true, 0,false,"交流输入1停电告警",1,pool);
+				//交流输入2停电告警			110122
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_User_AcIn2_PowerDown_ID,SqlsUtils.Alarm_Level_First,100,true, 0,false,"交流输入2停电告警",1,pool);
+				//交流1采集通信故障告警			110123
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_User_AcIn1_CommErr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流1采集通信故障告警",1,pool);
+				//交流2采集通信故障告警			110124
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_User_AcIn2_CommErr_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"交流2采集通信故障告警",1,pool);
+				//温感1通信故障告警				110125
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Temp1_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"温感1通信故障告警",1,pool);
+				//温感2通信故障告警				110126
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Temp2_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"温感2通信故障告警",1,pool);
+				//温感3通信故障告警				110127
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Temp3_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"温感3通信故障告警",1,pool);
+				//湿感1通信故障告警				110128
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Humi1_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"湿感1通信故障告警",1,pool);
+				//湿感2通信故障告警				110129
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Humi2_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"湿感2通信故障告警",1,pool);
+				//湿感3通信故障告警				110130
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Humi3_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"湿感3通信故障告警",1,pool);
+				//烟感1报警告警				110131
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke1_Occur_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"烟感1报警告警",1,pool);
+				//烟感2报警告警				110132
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke2_Occur_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"烟感2报警告警",1,pool);
+				//烟感3报警告警				110133
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke3_Occur_ID,SqlsUtils.Alarm_Level_Second,100,true, 0,false,"烟感3报警告警",1,pool);
+				//烟感1通信故障告警				110134
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke1_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"烟感1通信故障告警",1,pool);
+				//烟感2通信故障告警				110135
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke2_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"烟感2通信故障告警",1,pool);
+				//烟感3通信故障告警				110136
+				checkPowerAlarmParam(buf_body,PowerDeviceId,SqlsUtils.ALM_TYPE_Envm_Smoke3_CommErr_ID,SqlsUtils.Alarm_Level_Third,100,true, 0,false,"烟感3通信故障告警",1,pool);
+				