iec_61850_forFoShanAES/src/com/dec/fbs9100/BTS_61850_SocketClient.java
@@ -172,7 +172,7 @@ FBS9100_Task_Thread_SQL.inseartOrUpdateFBS9100SFODParam(m_ConnPool, m_StatAndParam.clParam, m_StatAndParam); FBS9100_Task_Thread_SQL.queryBTS61850OffLineyhPlanOnRam(m_ConnPool, m_StatAndParam); if(parseDevVersion(m_StatAndParam.m_DevVersion) >= 3.0) { //if(parseDevVersion(m_StatAndParam.m_DevVersion) >= 3.0) { //当协转版本不低于于3.0时需要检测UKEY //m_StatAndParam.keyID = readStringNodeData(FBSDeviceName + "/ncdGGIO1.Key_ID.d", Fc.DC); //ukeyID字符串 //m_StatAndParam.serialNumber = readStringNodeData(FBSDeviceName + "/ncdGGIO1.Bts_ID.d", Fc.DC); //唯一序列号 btsid @@ -180,7 +180,7 @@ m_StatAndParam.keyID = readStringNodeData(FBSDeviceName+"/btgGGIO1.ukeyID.d",Fc.DC); m_StatAndParam.serialNumber = readStringNodeData(FBSDeviceName+"/btgGGIO1.Bts_ID.d",Fc.DC); //唯一序列号 BTS61850_Task_Thread_SQL.UpdateBattInfTable(m_ConnPool, m_StatAndParam); //更新当前参数 } //} //读取主从机功能使能 @@ -1706,7 +1706,7 @@ //System.err.println("签名:"+signature); if(m_StatAndParam.serialNumber.trim().length() > 0 && m_StatAndParam.keyID.trim().length() > 0) { String signature = createSignature(m_StatAndParam.serialNumber+moderoot, m_StatAndParam.keyID); //生成签名 //System.out.println("写入签名"+signature); System.out.println("写入签名"+signature); /** * 佛山版ukey值btg中,南网标准版在ncdg */ iec_61850_forFoShanAES/src/com/dec/fbs9100/BattResStorePro_Thread.java
@@ -82,7 +82,11 @@ sql.sqlMysqlExecute(sql_str); } int mtest_record_count = 0;//sql.getBattTestRecordCountNew(data_rt.BattGroupId, Sql_Mysql.BattResDataInf_Table); /** * 修复记录内阻数据时,test_record_count 一直是0bug */ //int mtest_record_count = 0;//sql.getBattTestRecordCountNew(data_rt.BattGroupId, Sql_Mysql.BattResDataInf_Table); int mtest_record_count = sql.getBattTestRecordCountNew(data_rt.BattGroupId, Sql_Mysql.BattResDataInf_Table); for(int c=0; c<3; c++) { iec_61850_forFoShanAES/src/com/dec/fbs9100/main_BTS_APP_IEC61850.java
@@ -27,7 +27,7 @@ /**************************************************************************/ /**************************************************************************/ public final static boolean app_debug = false; public final static double m_VersionNum = 3.324; public final static double m_VersionNum = 3.325; public final static String m_Version = "Welcome To Use BattMonitor_BTS_IEC61850 V" + m_VersionNum + " RC_20201003"; /**************************************************************************/ iec_61850_forFoShanAES/src/com/version_inf/version_inf.txt
@@ -76,4 +76,7 @@ 2. 均衡电压设置修改为浮点数修改 V3.324 edit by lijun @ 2021-10-22 1.佛山二期修改,新增兼容两组BTS,修改设置UKEY点位信息动态传递 1.佛山二期修改,新增兼容两组BTS,修改设置UKEY点位信息动态传递 V3.325 edit by lijun @ 2021-10-22 1.修复:记录放电数据时,记录一笔内阻数据时test_record_count = 0