| | | import java.util.Date;
|
| | |
|
| | | import com.base.ComBase;
|
| | | import com.base.ComFn;
|
| | | import com.modbus.data.MyModbusMaster;
|
| | | import com.modbus.data.MyModbusUtils;
|
| | | import com.serotonin.modbus4j.BatchRead;
|
| | |
| | | */
|
| | | public void putHeadBatchResult(BatchResults<Integer> res) {
|
| | | if(res != null) {
|
| | | this.load_power = MyModbusUtils.readShortToFloat(res.getValue(0)); //加载功率给定 58 |
| | | this.load_torque = MyModbusUtils.readShortToFloat(res.getValue(1)); //加载转矩给定 364 |
| | | //System.out.println(res.getValue(0));
|
| | | short f = (Short)res.getValue(0);
|
| | | this.load_power = MyModbusUtils.readShortToFloat(res.getValue(0),true); //加载功率给定 58 |
| | | this.load_torque = MyModbusUtils.readShortToFloat(res.getValue(1),true); //加载转矩给定 364 |
| | | this.load_motor_speed_limit = MyModbusUtils.readIntegerToFloat(res.getValue(2)); //加载电机转速限制 366
|
| | | this.load_motor_torque_limit = MyModbusUtils.readShortToFloat(res.getValue(3)); //加载电机转矩限制 367
|
| | | this.load_motor_torque_limit = MyModbusUtils.readShortToFloat(res.getValue(3),true); //加载电机转矩限制 367
|
| | | this.load_step_length = MyModbusUtils.readIntegerToFloat(res.getValue(4)); //加载步长 505
|
| | | this.load_motor_inwater_tmp = MyModbusUtils.readIntegerToFloat(res.getValue(5)); //加载电机水冷进水风温 1006
|
| | | this.load_motor_outwater_tmp = MyModbusUtils.readIntegerToFloat(res.getValue(6)); //加载电机水冷出水风温 1008
|
| | | this.load_motor_curr = MyModbusUtils.readShortToFloat(res.getValue(7)); //加载电机电流 1096
|
| | | this.load_motor_power = MyModbusUtils.readShortToFloat(res.getValue(8)); //加载电机功率 1099
|
| | | this.load_motor_curr = MyModbusUtils.readShortToFloat(res.getValue(7),true); //加载电机电流 1096
|
| | | this.load_motor_power = MyModbusUtils.readShortToFloat(res.getValue(8),true); //加载电机功率 1099
|
| | | this.record_time = new Date();
|
| | | }
|
| | | }
|
| | |
| | | */
|
| | | public void putBodyBatchResult(BatchResults<Integer> res) {
|
| | | if(res != null) {
|
| | | this.load_motor_speed = MyModbusUtils.readShortToFloat(res.getValue(9)); //加载电机转速 1101
|
| | | this.load_motor_vol = MyModbusUtils.readShortToFloat(res.getValue(10)); //加载电机电压 1103
|
| | | this.load_motor_wind_tmp1 = MyModbusUtils.readShortToFloat(res.getValue(11)); //加载电机绕组温度1 1119
|
| | | this.load_motor_wind_tmp2 = MyModbusUtils.readShortToFloat(res.getValue(12)); //加载电机绕组温度2 1120
|
| | | this.load_motor_wind_tmp3 = MyModbusUtils.readShortToFloat(res.getValue(13)); //加载电机绕组温度3 1121
|
| | | this.load_motor_bear_tmp1 = MyModbusUtils.readShortToFloat(res.getValue(14)); //加载电机轴承温度1 1122
|
| | | this.load_motor_bear_tmp2 = MyModbusUtils.readShortToFloat(res.getValue(15)); //加载电机轴承温度2 1123
|
| | | this.load_motor_out_tmp = MyModbusUtils.readShortToFloat(res.getValue(16)); //加载电机出口温度 1250
|
| | | this.load_motor_into_tmp = MyModbusUtils.readShortToFloat(res.getValue(17)); //加载电机进口温度 1124
|
| | | this.load_motor_torque = MyModbusUtils.readShortToFloat(res.getValue(18)); //加载电机转矩 1251
|
| | | this.load_motor_speed = MyModbusUtils.readShortToFloat(res.getValue(9),true); //加载电机转速 1101
|
| | | this.load_motor_vol = MyModbusUtils.readShortToFloat(res.getValue(10),true); //加载电机电压 1103
|
| | | this.load_motor_wind_tmp1 = MyModbusUtils.readShortToFloat(res.getValue(11),true); //加载电机绕组温度1 1119
|
| | | this.load_motor_wind_tmp2 = MyModbusUtils.readShortToFloat(res.getValue(12),true); //加载电机绕组温度2 1120
|
| | | this.load_motor_wind_tmp3 = MyModbusUtils.readShortToFloat(res.getValue(13),true); //加载电机绕组温度3 1121
|
| | | this.load_motor_bear_tmp1 = MyModbusUtils.readShortToFloat(res.getValue(14),true); //加载电机轴承温度1 1122
|
| | | this.load_motor_bear_tmp2 = MyModbusUtils.readShortToFloat(res.getValue(15),true); //加载电机轴承温度2 1123
|
| | | this.load_motor_out_tmp = MyModbusUtils.readShortToFloat(res.getValue(16),true); //加载电机出口温度 1250
|
| | | this.load_motor_into_tmp = MyModbusUtils.readShortToFloat(res.getValue(17),true); //加载电机进口温度 1124
|
| | | this.load_motor_torque = MyModbusUtils.readShortToFloat(res.getValue(18),true); //加载电机转矩 1251
|
| | | this.load_motor_start = MyModbusUtils.readBooleanToInt(res.getValue(19)); //加载电机启动 5680
|
| | | this.load_motor_downtime = MyModbusUtils.readBooleanToInt(res.getValue(20)); //加载电机停机 5681
|
| | | this.load_add = MyModbusUtils.readBooleanToInt(res.getValue(21)); //加载 8000
|
| | |
| | | this.load_motor_stop = MyModbusUtils.readBooleanToInt(res.getValue(24)); //加载电机紧停 16005
|
| | | this.load_motor_fan_state = MyModbusUtils.readBooleanToInt(res.getValue(25)); //加载电机风机状态 17082
|
| | |
|
| | | this.load_motor_wind_tmp1_bp = MyModbusUtils.readShortToFloat(res.getValue(26)); //备用加载电机绕组温度1 1122
|
| | | this.load_motor_wind_tmp2_bp = MyModbusUtils.readShortToFloat(res.getValue(27)); //备用加载电机绕组温度2 1123 |
| | | this.load_motor_wind_tmp3_bp = MyModbusUtils.readShortToFloat(res.getValue(28)); //备用加载电机绕组温度3 1124
|
| | | this.load_motor_wind_tmp1_bp = MyModbusUtils.readShortToFloat(res.getValue(26),true); //备用加载电机绕组温度1 1122
|
| | | this.load_motor_wind_tmp2_bp = MyModbusUtils.readShortToFloat(res.getValue(27),true); //备用加载电机绕组温度2 1123 |
| | | this.load_motor_wind_tmp3_bp = MyModbusUtils.readShortToFloat(res.getValue(28),true); //备用加载电机绕组温度3 1124
|
| | | this.record_time = new Date();
|
| | | }
|
| | | }
|