| | | 2023-09-25 14:07:56.064 [Thread-12] [ERROR] com.battalarm.BattAlarm_Thread_New2 - java.lang.NullPointerException
|
| | | java.lang.NullPointerException: null
|
| | | at com.battalarm.BattAlarm_Thread_New2.insertOrUpdateBattAlarmDataToTable(BattAlarm_Thread_New2.java:722) ~[bin/:?]
|
| | | at com.battalarm.BattAlarm_Thread_New2.run(BattAlarm_Thread_New2.java:1153) [bin/:?]
|
| | | 2024-09-26 13:37:02.867 [main] [ERROR] com.sql.MysqlConnPool - MysqlConnPool.getConn()java.sql.SQLException: Connections could not be acquired from the underlying database!
|
| | | java.sql.SQLException: Connections could not be acquired from the underlying database!
|
| | | at com.mchange.v2.sql.SqlUtils.toSQLException(SqlUtils.java:118) ~[mchange-commons-java-0.2.9.jar:0.2.9]
|
| | | at com.mchange.v2.c3p0.impl.C3P0PooledConnectionPool.checkoutPooledConnection(C3P0PooledConnectionPool.java:690) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.mchange.v2.c3p0.impl.AbstractPoolBackedDataSource.getConnection(AbstractPoolBackedDataSource.java:140) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.sql.MysqlConnPool.getConn(MysqlConnPool.java:43) [bin/:?]
|
| | | at main.main_FBS9100S_Alarm.checkingMySQLServerStart(main_FBS9100S_Alarm.java:269) [bin/:?]
|
| | | at main.main_FBS9100S_Alarm.main(main_FBS9100S_Alarm.java:155) [bin/:?]
|
| | | Caused by: com.mchange.v2.resourcepool.CannotAcquireResourceException: A ResourcePool could not acquire a resource from its primary factory or source.
|
| | | at com.mchange.v2.resourcepool.BasicResourcePool.awaitAvailable(BasicResourcePool.java:1463) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.mchange.v2.resourcepool.BasicResourcePool.prelimCheckoutResource(BasicResourcePool.java:639) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.mchange.v2.resourcepool.BasicResourcePool.checkoutResource(BasicResourcePool.java:549) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.mchange.v2.c3p0.impl.C3P0PooledConnectionPool.checkoutAndMarkConnectionInUse(C3P0PooledConnectionPool.java:756) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | at com.mchange.v2.c3p0.impl.C3P0PooledConnectionPool.checkoutPooledConnection(C3P0PooledConnectionPool.java:683) ~[c3p0-0.9.5.jar:0.9.5]
|
| | | ... 4 more
|
| | |
| | | 2024-07-02 14:32:59.837 [main] [INFO] main.main_FBS9100S_Alarm - /****************************************************************
|
| | | 2024-07-02 14:32:59.845 [main] [INFO] main.main_FBS9100S_Alarm - *****************************************************************
|
| | | 2024-07-02 14:32:59.846 [main] [INFO] main.main_FBS9100S_Alarm - ****************************************************************/
|
| | | 2024-07-02 14:32:59.846 [main] [INFO] main.main_FBS9100S_Alarm - Welcome To Use FBS9100S Alarm Mornitor V2.22 RC_20170505 app_for_fbs_free_only
|
| | | 2024-07-02 14:32:59.870 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1 port:3360
|
| | | 2024-07-02 14:33:00.224 [main] [INFO] main.main_FBS9100S_Alarm - 开始检测数据库连接 2024-07-02 14:33:00
|
| | | 2024-07-02 14:33:00.422 [main] [INFO] main.main_FBS9100S_Alarm - 检测数据库连接成功
|
| | | 2024-07-02 14:33:00.422 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1port3360
|
| | | 2024-07-02 14:33:00.452 [main] [WARN] com.battdata_rt.BattData_RT_Array - run initBattDataRT_Inf_FromSQL()
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig start -----------------------------------
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - MysqlServerIp=127.0.0.1
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - SybaseServerIp=127.0.0.1
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - MysqlConnCountMax=400
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - WorkThreadCountMax=300
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - SourceBattDataType=0
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - FbsDeviceBaseIp=192.168.0.1
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnEn=false
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnStartDelay=1
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmClearedDelay=1
|
| | | 2024-07-02 14:33:00.456 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreFnEn=false
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDelayForTestManual=1200
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDayInterval=7
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig end -----------------------------------
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param start---------------------------------
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:33:00.457 [main] [INFO] main.main_FBS9100S_Alarm - Charge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Charge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Charge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestTimeLongMinimum=1800
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattJunHengFN=false
|
| | | 2024-07-02 14:33:00.458 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param end---------------------------------
|
| | | 2024-07-02 14:33:00.504 [Thread-10] [INFO] com.battalarm.DeviceAlarm_Thread_New2 - Thread-10 - DevAlarm_Thread Started at 2024-07-02 14:33:00
|
| | | 2024-07-02 14:33:00.560 [Thread-14] [INFO] com.battalarm.BattDevHistory_SubtableThread - BattDevHistory_SubtableThread Start at 2024-07-02 14:33:00
|
| | | 2024-07-02 14:33:00.562 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Delayed For 1 Seconds To Start...
|
| | | 2024-07-02 14:33:00.563 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Started at 2024-07-02 14:33:00
|
| | | 2024-07-02 14:35:22.844 [main] [INFO] main.main_FBS9100S_Alarm - /****************************************************************
|
| | | 2024-07-02 14:35:22.846 [main] [INFO] main.main_FBS9100S_Alarm - *****************************************************************
|
| | | 2024-07-02 14:35:22.846 [main] [INFO] main.main_FBS9100S_Alarm - ****************************************************************/
|
| | | 2024-07-02 14:35:22.846 [main] [INFO] main.main_FBS9100S_Alarm - Welcome To Use FBS9100S Alarm Mornitor V2.22 RC_20170505 app_for_fbs_free_only
|
| | | 2024-07-02 14:35:22.869 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1 port:3360
|
| | | 2024-07-02 14:35:23.191 [main] [INFO] main.main_FBS9100S_Alarm - 开始检测数据库连接 2024-07-02 14:35:23
|
| | | 2024-07-02 14:35:23.366 [main] [INFO] main.main_FBS9100S_Alarm - 检测数据库连接成功
|
| | | 2024-07-02 14:35:23.366 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1port3360
|
| | | 2024-07-02 14:35:23.394 [main] [WARN] com.battdata_rt.BattData_RT_Array - run initBattDataRT_Inf_FromSQL()
|
| | | 2024-07-02 14:35:23.398 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig start -----------------------------------
|
| | | 2024-07-02 14:35:23.398 [main] [INFO] main.main_FBS9100S_Alarm - MysqlServerIp=127.0.0.1
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - SybaseServerIp=127.0.0.1
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - MysqlConnCountMax=400
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - WorkThreadCountMax=300
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - SourceBattDataType=0
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - FbsDeviceBaseIp=192.168.0.1
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnEn=false
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnStartDelay=1
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmClearedDelay=1
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreFnEn=false
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDelayForTestManual=1200
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDayInterval=7
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig end -----------------------------------
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param start---------------------------------
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:35:23.399 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Charge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Charge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Charge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestTimeLongMinimum=1800
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:35:23.400 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:35:23.401 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:35:23.401 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:35:23.401 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattJunHengFN=false
|
| | | 2024-07-02 14:35:23.401 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param end---------------------------------
|
| | | 2024-07-02 14:35:23.421 [Thread-10] [INFO] com.battalarm.DeviceAlarm_Thread_New2 - Thread-10 - DevAlarm_Thread Started at 2024-07-02 14:35:23
|
| | | 2024-07-02 14:35:23.436 [Thread-14] [INFO] com.battalarm.BattDevHistory_SubtableThread - BattDevHistory_SubtableThread Start at 2024-07-02 14:35:23
|
| | | 2024-07-02 14:35:23.440 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Delayed For 1 Seconds To Start...
|
| | | 2024-07-02 14:35:23.440 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Started at 2024-07-02 14:35:23
|
| | | 2024-07-02 14:38:02.687 [main] [INFO] main.main_FBS9100S_Alarm - /****************************************************************
|
| | | 2024-07-02 14:38:02.690 [main] [INFO] main.main_FBS9100S_Alarm - *****************************************************************
|
| | | 2024-07-02 14:38:02.690 [main] [INFO] main.main_FBS9100S_Alarm - ****************************************************************/
|
| | | 2024-07-02 14:38:02.690 [main] [INFO] main.main_FBS9100S_Alarm - Welcome To Use FBS9100S Alarm Mornitor V2.22 RC_20170505 app_for_fbs_free_only
|
| | | 2024-07-02 14:38:02.714 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1 port:3360
|
| | | 2024-07-02 14:38:03.044 [main] [INFO] main.main_FBS9100S_Alarm - 开始检测数据库连接 2024-07-02 14:38:03
|
| | | 2024-07-02 14:38:03.223 [main] [INFO] main.main_FBS9100S_Alarm - 检测数据库连接成功
|
| | | 2024-07-02 14:38:03.223 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1port3360
|
| | | 2024-07-02 14:38:03.253 [main] [WARN] com.battdata_rt.BattData_RT_Array - run initBattDataRT_Inf_FromSQL()
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig start -----------------------------------
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - MysqlServerIp=127.0.0.1
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - SybaseServerIp=127.0.0.1
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - MysqlConnCountMax=400
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - WorkThreadCountMax=300
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - SourceBattDataType=0
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - FbsDeviceBaseIp=192.168.0.1
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnEn=false
|
| | | 2024-07-02 14:38:03.257 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnStartDelay=1
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmClearedDelay=1
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreFnEn=false
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDelayForTestManual=1200
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDayInterval=7
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig end -----------------------------------
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param start---------------------------------
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:38:03.258 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestTimeLongMinimum=60
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Charge_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Charge_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Charge_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestTimeLongMinimum=1800
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_SaveDataTimeInterval=10
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_MonVolChangeLevel=0.05
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_BattTestGroupCountMax=10
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestDataRecordCountMax=10000
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattJunHengFN=false
|
| | | 2024-07-02 14:38:03.259 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param end---------------------------------
|
| | | 2024-07-02 14:38:03.280 [Thread-10] [INFO] com.battalarm.DeviceAlarm_Thread_New2 - Thread-10 - DevAlarm_Thread Started at 2024-07-02 14:38:03
|
| | | 2024-07-02 14:38:03.293 [Thread-14] [INFO] com.battalarm.BattDevHistory_SubtableThread - BattDevHistory_SubtableThread Start at 2024-07-02 14:38:03
|
| | | 2024-07-02 14:38:03.295 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Delayed For 1 Seconds To Start...
|
| | | 2024-07-02 14:38:03.295 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Started at 2024-07-02 14:38:03
|
| | | 2024-12-23 16:18:34.012 [main] [INFO] main.main_FBS9100S_Alarm - /****************************************************************
|
| | | 2024-12-23 16:18:34.023 [main] [INFO] main.main_FBS9100S_Alarm - *****************************************************************
|
| | | 2024-12-23 16:18:34.023 [main] [INFO] main.main_FBS9100S_Alarm - ****************************************************************/
|
| | | 2024-12-23 16:18:34.023 [main] [INFO] main.main_FBS9100S_Alarm - Welcome To Use FBS9100S Alarm Mornitor V2.221 RC_20170505 app_for_fbs_free_only
|
| | | 2024-12-23 16:18:34.058 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1 port:3360
|
| | | 2024-12-23 16:18:34.982 [main] [INFO] main.main_FBS9100S_Alarm - 开始检测数据库连接 2024-12-23 16:18:34
|
| | | 2024-12-23 16:18:35.190 [main] [INFO] main.main_FBS9100S_Alarm - 检测数据库连接成功
|
| | | 2024-12-23 16:18:35.190 [main] [INFO] main.main_FBS9100S_Alarm - IP:127.0.0.1port3360
|
| | | 2024-12-23 16:18:35.275 [main] [WARN] com.battdata_rt.BattData_RT_Array - run initBattDataRT_Inf_FromSQL()
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig start -----------------------------------
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - MysqlServerIp=127.0.0.1
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - SybaseServerIp=127.0.0.1
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - MysqlConnCountMax=400
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - WorkThreadCountMax=300
|
| | | 2024-12-23 16:18:35.297 [main] [INFO] main.main_FBS9100S_Alarm - SourceBattDataType=0
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - FbsDeviceBaseIp=192.168.0.1
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnEn=false
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmFnStartDelay=1
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattAlarmClearedDelay=1
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreFnEn=false
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDelayForTestManual=1200
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - BattResStoreDayInterval=7
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - ------------------- AppConfig end -----------------------------------
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param start---------------------------------
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestTimeLongMinimum=60
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_SaveDataTimeInterval=10
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_MonVolChangeLevel=0.05
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattTestGroupCountMax=10
|
| | | 2024-12-23 16:18:35.298 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_TestDataRecordCountMax=10000
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestTimeLongMinimum=60
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Charge_SaveDataTimeInterval=10
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Charge_MonVolChangeLevel=0.05
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Charge_BattTestGroupCountMax=10
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Charge_TestDataRecordCountMax=10000
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestTimeLongMinimum=1800
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_SaveDataTimeInterval=10
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_MonVolChangeLevel=0.05
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_BattTestGroupCountMax=10
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - Poweroff_TestDataRecordCountMax=10000
|
| | | 2024-12-23 16:18:35.299 [main] [INFO] main.main_FBS9100S_Alarm - --------------------------------------------------------------------
|
| | | 2024-12-23 16:18:35.300 [main] [INFO] main.main_FBS9100S_Alarm - Discharge_BattJunHengFN=false
|
| | | 2024-12-23 16:18:35.300 [main] [INFO] main.main_FBS9100S_Alarm - --------------------- App_Param end---------------------------------
|
| | | 2024-12-23 16:18:35.383 [Thread-10] [INFO] com.battalarm.DeviceAlarm_Thread_New2 - Thread-10 - DevAlarm_Thread Started at 2024-12-23 16:18:35
|
| | | 2024-12-23 16:18:35.434 [Thread-14] [INFO] com.battalarm.BattDevHistory_SubtableThread - BattDevHistory_SubtableThread Start at 2024-12-23 16:18:35
|
| | | 2024-12-23 16:18:35.438 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Delayed For 1 Seconds To Start...
|
| | | 2024-12-23 16:18:35.439 [Thread-12] [INFO] com.battalarm.BattAlarm_Thread_New2 - Thread-12 - BattAlarm_Thread Started at 2024-12-23 16:18:35
|
| | |
| | | */
|
| | | public BattAlarmParam()
|
| | | {
|
| | | alm_OnlineVol = new AlarmParamCell((float)1.177, (float)1.075, 1, 1, true, true, 1.185f, 1.062f, true, true,60,1,1);
|
| | | alm_GroupVol = new AlarmParamCell((float)1.177, (float)1.075, 2, 2, true, true, 1.185f, 1.062f, true, true,60,2,2);
|
| | | alm_BattChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 10f, 0, true, false,60,3,3);
|
| | | alm_BattDisChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 10f,0, true, false,60,3,3);
|
| | |
|
| | | alm_MonVol = new AlarmParamCell((float)1.175, (float)0.9, 4, 4, true, true, 1.2f, 0.85f, true, true,60,4,4);
|
| | | alm_MonTmp = new AlarmParamCell((float)1.5, (float)0.2, 4, 4, false, false, 1.6f, 0.12f,false , false,60,4,4);
|
| | | /***
|
| | | * 国网默认核容告警参数
|
| | | */
|
| | | // alm_OnlineVol = new AlarmParamCell((float)1.177, (float)1.075, 1, 1, true, true, 1.185f, 1.062f, true, true,60,1,1);
|
| | | // alm_GroupVol = new AlarmParamCell((float)1.177, (float)1.075, 2, 2, true, true, 1.185f, 1.062f, true, true,60,2,2);
|
| | | // alm_BattChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 10f, 0, true, false,60,3,3);
|
| | | // alm_BattDisChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 10f,0, true, false,60,3,3);
|
| | | // |
| | | // alm_MonVol = new AlarmParamCell((float)1.175, (float)0.9, 4, 4, true, true, 1.2f, 0.85f, true, true,60,4,4);
|
| | | // alm_MonTmp = new AlarmParamCell((float)1.5, (float)0.2, 4, 4, false, false, 1.6f, 0.12f,false , false,60,4,4);
|
| | | // |
| | | // alm_MonRes = new AlarmParamCell((float)1.2, (float)0.5, 1, 4, false, false, 1.22f, 0.1f, true, false,60,1,4);
|
| | | // alm_ConnRes = new AlarmParamCell((float)2, (float)0.5, 4, 4, false, false, 4f, 0.1f, false, false,60,4,4);
|
| | | // |
| | | // alm_DischargeMonVol = new AlarmParamCell((float)1.2, (float)0.8, 4, 4, false, false, 1.75f, 0.6f, false, false,60,4,4);
|
| | | // |
| | | // alm_MonLYVol = new AlarmParamCell((float)1.2, (float)0.7, 4, 4, true, false, 1.4f, 0.5f, true , false,60,4,4);
|
| | | // |
| | | // alm_MonREALCAP = new AlarmParamCell((float)1.1,(float) 0.8, 3, 3, false, false, 1.3f, 0.6f, false, false,60,3,3);
|
| | |
|
| | | /***
|
| | | * 南网默认核容告警参数 - 南瑞
|
| | | */
|
| | | alm_OnlineVol = new AlarmParamCell((float)1.18, (float)1.075, 1, 1, true, true, 1.2f, 1.062f, true, true,60,1,1);
|
| | | alm_GroupVol = new AlarmParamCell((float)1.18, (float)1.075, 2, 2, true, true, 1.2f, 1.062f, true, true,60,2,2);
|
| | | alm_BattChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 3.2f, 0, true, false,60,3,3);
|
| | | alm_BattDisChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false, 3.2f,0, true, false,60,3,3);
|
| | | |
| | | alm_MonVol = new AlarmParamCell((float)1.2, (float)0.9, 4, 4, true, true, 1.25f, 0f, true, true,60,4,4);
|
| | | alm_MonTmp = new AlarmParamCell((float)1.2, (float)0.5, 4, 4, true, false, 1.6f, 0f,true , true,60,4,4);
|
| | |
|
| | | alm_MonRes = new AlarmParamCell((float)1.2, (float)0.5, 1, 4, false, false, 1.22f, 0.1f, true, false,60,1,4);
|
| | | alm_ConnRes = new AlarmParamCell((float)2, (float)0.5, 4, 4, false, false, 4f, 0.1f, false, false,60,4,4);
|
| | |
| | | alm_MonLYVol = new AlarmParamCell((float)1.2, (float)0.7, 4, 4, true, false, 1.4f, 0.5f, true , false,60,4,4);
|
| | |
|
| | | alm_MonREALCAP = new AlarmParamCell((float)1.1,(float) 0.8, 3, 3, false, false, 1.3f, 0.6f, false, false,60,3,3);
|
| | |
|
| | | |
| | | |
| | | /* alm_OnlineVol = new AlarmParamCell((float)1.125, (float)0.9, 1, 1, true, true);
|
| | | alm_GroupVol = new AlarmParamCell((float)1.125, (float)0.9, 2, 2, true, true);
|
| | | alm_BattChargeCurr = new AlarmParamCell((float)3, (float)0, 3, 3, true, false);
|
| | |
| | | import java.sql.ResultSet;
|
| | | import java.sql.SQLException;
|
| | | import java.util.ArrayList;
|
| | | import java.util.Arrays;
|
| | | import java.util.Date;
|
| | | import java.util.List;
|
| | | import java.util.Map;
|
| | |
| | | mysql_ds.setJdbcUrl("jdbc:mysql://" + server_ip + ":" + mSqlPort);
|
| | | mysql_ds.setUser("root");
|
| | | mysql_ds.setPassword("lmx8688139");
|
| | | // mysql_ds.setUser("whyc"); //天一电厂账号
|
| | | // mysql_ds.setPassword("Fg001@hdw"); //天一电厂密码
|
| | | mysql_ds.setMaxPoolSize(conncount_max);
|
| | | mysql_ds.setMinPoolSize(2);
|
| | | mysql_ds.setIdleConnectionTestPeriod(60);
|