新疆锂电通信程序,兼容【常规BTS,老版本并联BTS;假负载BTS,逆变BTS】
V10.653 edit at date 2023-06-17 lijun
1.远程升级后不重置读取状态 ok-3 方便平台显示升级完状态
6个文件已修改
11 ■■■■ 已修改文件
BattMonitor_FBS9100S_ForXinJiang/bin/com/dev/btse/comm/FBS9100S_SocketClient2.class 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/bin/com/version_inf/version_inf.txt 2 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/bin/main/main_MonitorServer_FBS9100S.class 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/src/com/dev/btse/comm/FBS9100S_SocketClient2.java 5 ●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/src/com/version_inf/version_inf.txt 2 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/src/main/main_MonitorServer_FBS9100S.java 2 ●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBS9100S_ForXinJiang/bin/com/dev/btse/comm/FBS9100S_SocketClient2.class
Binary files differ
BattMonitor_FBS9100S_ForXinJiang/bin/com/version_inf/version_inf.txt
@@ -1,4 +1,6 @@
V10.653 edit at date 2023-06-17 lijun
    1.远程升级后不重置读取状态        ok-3  方便平台显示升级完状态
V10.652 edit at date 2023-05-31 lijun
    1.记录历史数据最后一笔数据时不记录仅更新最后一笔的停止原因,修复最后一笔数据电流回升问题
BattMonitor_FBS9100S_ForXinJiang/bin/main/main_MonitorServer_FBS9100S.class
Binary files differ
BattMonitor_FBS9100S_ForXinJiang/src/com/dev/btse/comm/FBS9100S_SocketClient2.java
@@ -620,7 +620,10 @@
                                    && (FBS9100S_DFU_SQL.DFU_STATE_CHECK_OK == m_FBS9100S_DFU.DFU_WR_State)) {
                                if(true == SocketComm(FBS9100_ComBase.CMD_SystemUpdate, ByteBuffer.allocate(0), socket)) {
                                    m_FBS9100S_DFU.DFU_EN = false;
                                    m_FBS9100S_DFU.DFU_WR_State = FBS9100S_DFU_SQL.DFU_STATE_NULL;
                                    /**
                                     * 2023-06-17 @lijun    升级完成不重置  读取状态
                                     */
                                    //m_FBS9100S_DFU.DFU_WR_State = FBS9100S_DFU_SQL.DFU_STATE_NULL;
                                    FBS9100S_DFU_SQL.updateFbs9100S_DFU_StatByDev_Id(m_ConnPool, m_StatAndParam.dev_id, m_FBS9100S_DFU);
                                    //System.out.println(String.format("DevId:%d, DFU Done, FBS9100S_DFU_SQL.updateFbs9100S_DFU_StatByDev_Id", 
                                    //                                    m_StatAndParam.dev_id));
BattMonitor_FBS9100S_ForXinJiang/src/com/version_inf/version_inf.txt
@@ -1,4 +1,6 @@
V10.653 edit at date 2023-06-17 lijun
    1.远程升级后不重置读取状态        ok-3  方便平台显示升级完状态
V10.652 edit at date 2023-05-31 lijun
    1.记录历史数据最后一笔数据时不记录仅更新最后一笔的停止原因,修复最后一笔数据电流回升问题
BattMonitor_FBS9100S_ForXinJiang/src/main/main_MonitorServer_FBS9100S.java
@@ -29,7 +29,7 @@
    /**************************************************************************/
    /**************************************************************************/
    public final static boolean app_debug = false;
    public final static double m_VersionNum = 10.652;
    public final static double m_VersionNum = 10.653;
    public final static String m_Version = "Welcome To Use BattMonitorFBS9100S V" 
                                            + m_VersionNum + " RC_20201110";
    /**************************************************************************/