Administrator
2023-06-01 55e2037a54ec68c91f31791eb761c58137b11035
V1.105  2023-05-16
1.通信方式修改成通过设备Id与设备编号连接
8个文件已修改
16 ■■■■ 已修改文件
BattMonitor_FBO_4831NT/bin/com/batttest/BattDataTestPro_Thread$MyBattTestTask.class 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/bin/com/dev/fgcd/comm/FGCD_SocketClient_Thread.class 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/bin/com/version_inf/version_inf.txt 3 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/bin/main/main_Monitor_FBO_4831.class 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/src/com/batttest/BattDataTestPro_Thread.java 2 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/src/com/dev/fgcd/comm/FGCD_SocketClient_Thread.java 6 ●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/src/com/version_inf/version_inf.txt 3 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/src/main/main_Monitor_FBO_4831.java 2 ●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_FBO_4831NT/bin/com/batttest/BattDataTestPro_Thread$MyBattTestTask.class
Binary files differ
BattMonitor_FBO_4831NT/bin/com/dev/fgcd/comm/FGCD_SocketClient_Thread.class
Binary files differ
BattMonitor_FBO_4831NT/bin/com/version_inf/version_inf.txt
@@ -2,6 +2,9 @@
    通信端口:        4831    
    设备ID:        48310000X
V1.105  2023-05-16
    1.通信方式修改成通过设备Id与设备编号连接
需求修改 
    1.设备静置状态不记录数据
    2.设备暂停状态时不记录放电数据,暂停结束后继续记录
BattMonitor_FBO_4831NT/bin/main/main_Monitor_FBO_4831.class
Binary files differ
BattMonitor_FBO_4831NT/src/com/batttest/BattDataTestPro_Thread.java
@@ -163,6 +163,8 @@
                    if((FGCD_ComBase.WORK_STATE_STOPDIS == rt_data.mTestData.dev_FBS9100S_WorkState)
                            || (FGCD_ComBase.WORK_STATE_STOPCHAR == rt_data.mTestData.dev_FBS9100S_WorkState)) {
                        //暂停放电或者充电时不记录数据
                        //清空数据更新
                        rt_data.al_MonVol_C_Id.clear();
                        continue;
                    }
                    
BattMonitor_FBO_4831NT/src/com/dev/fgcd/comm/FGCD_SocketClient_Thread.java
@@ -131,13 +131,13 @@
                        byte[] dev_ipaddr = m_Data.getItem(i).FBSDevIp;
                        int dev_id_t = m_Data.getItem(i).FBSDeviceId;
                        //System.err.println(m_Data.getItem(i).FBSDeviceId+" =="+ m_StatAndParam.check_dev_id);
                        //if(m_Data.getItem(i).FBSDeviceId == m_StatAndParam.check_dev_id) {
                        if(m_Data.getItem(i).dev_num.equals(m_StatAndParam.dev_num+"")) {
                        if(m_Data.getItem(i).FBSDeviceId == m_StatAndParam.check_dev_id) {
                        //if(m_Data.getItem(i).dev_num.equals(m_StatAndParam.dev_num+"")) {
                            m_StatAndParam.dev_id = dev_id_t;
                            dfu_state.dev_id = dev_id_t;
                            //DevFBS9100_Encry_en =  m_Data.getItem(i).aescode_en;
                            reg_in_st = true;
                            logger.debug("Find DevID:" + m_StatAndParam.dev_id + " OK DevNum:" + m_StatAndParam.dev_num);
                            logger.debug("Find DevID:" + m_StatAndParam.dev_id + " OK check_dev_id:" + m_StatAndParam.check_dev_id);
                        }
                        if(true == reg_in_st) {
                            break;
BattMonitor_FBO_4831NT/src/com/version_inf/version_inf.txt
@@ -2,6 +2,9 @@
    通信端口:        4831    
    设备ID:        48310000X
V1.105  2023-05-16
    1.通信方式修改成通过设备Id与设备编号连接
需求修改 
    1.设备静置状态不记录数据
    2.设备暂停状态时不记录放电数据,暂停结束后继续记录
BattMonitor_FBO_4831NT/src/main/main_Monitor_FBO_4831.java
@@ -18,7 +18,7 @@
public class main_Monitor_FBO_4831 {
    public final static double m_VersionNum = 1.104;
    public final static double m_VersionNum = 1.105;
    public final static String m_Version = "Welcome To Use main_Monitor_FBO_4830 PRO 20210714 V" 
                                            + m_VersionNum ;
    /**************************************************************************/