V1.65 edit at date 2024-04-04
1.db_ram_db.tb_fbs9100_state表扩展版本号长度,FBS300版本号超出原本长度,扩展设备版本号字段
`dev_version` varchar(255) NOT NULL DEFAULT '',
2.后台线程管理新增 FBC4831线程 - ProcessId = 11025
sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table +
"(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime)
VALUES ('11025', 'BMS_BATT_FBC_4831NT', '1970-01-01 00:00:00',
'1970-01-01 00:00:00', 'BMS_BATT_FBC_4831NT', '2', 'v1.100',
'FBC4831通信线程', '300');");
3.创建并联BTS拓扑状态信息表 'db_ram_db.tb_fbs9140_topology_state'
| | |
| | | 蓄电池监控平台建表程序 |
| | | |
| | | V1.65 edit at date 2024-04-04 |
| | | 1.db_ram_db.tb_fbs9100_state表扩展版本号长度,FBS300版本号超出原本长度,扩展设备版本号字段 |
| | | `dev_version` varchar(255) NOT NULL DEFAULT '', |
| | | 2.后台线程管理新增 FBC4831线程 - ProcessId = 11025 |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11025', 'BMS_BATT_FBC_4831NT', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_BATT_FBC_4831NT', '2', 'v1.100', 'FBC4831通信线程', '300');"); |
| | | 3.创建并联BTS拓扑状态信息表 'db_ram_db.tb_fbs9140_topology_state' |
| | | CREATE TABLE `tb_fbs9140_topology_state` ( |
| | | `num` bigint(20) NOT NULL AUTO_INCREMENT COMMENT '主键', |
| | | `dev_id` int(11) NOT NULL DEFAULT '0' COMMENT '设备id', |
| | | `record_time` datetime NOT NULL DEFAULT '2000-01-01 00:00:00' COMMENT '记录时间', |
| | | `grouptotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '电池组总数', |
| | | `montotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '单体总数', |
| | | `onlinevol` float NOT NULL DEFAULT '0' COMMENT '在线电压', |
| | | `accurrrindex` int(11) NOT NULL DEFAULT '0' COMMENT '当前AC输入索引[0-#1 1-#2]', |
| | | `acua_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电压', |
| | | `acub_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电压', |
| | | `acuc_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电压', |
| | | `acia_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电流', |
| | | `acib_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电流', |
| | | `acic_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电流', |
| | | `acua_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电压', |
| | | `acub_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电压', |
| | | `acuc_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电压', |
| | | `acia_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电流', |
| | | `acib_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电流', |
| | | `acic_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电流', |
| | | `mod_enable1` int(11) NOT NULL DEFAULT '0' COMMENT '组1模块使能状态[0-断开 1-闭合]', |
| | | `batt_state1` int(11) NOT NULL DEFAULT '0' COMMENT '组1电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol1` float NOT NULL DEFAULT '0' COMMENT '组1输出电压', |
| | | `mod_outcurr1` float NOT NULL DEFAULT '0' COMMENT '组1输出电流', |
| | | `mod_enable2` int(11) NOT NULL DEFAULT '0' COMMENT '组2模块使能状态[0-断开 1-闭合]', |
| | | `batt_state2` int(11) NOT NULL DEFAULT '0' COMMENT '组2电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol2` float NOT NULL DEFAULT '0' COMMENT '组2输出电压', |
| | | `mod_outcurr2` float NOT NULL DEFAULT '0' COMMENT '组2输出电流', |
| | | `mod_enable3` int(11) NOT NULL DEFAULT '0' COMMENT '组3模块使能状态[0-断开 1-闭合]', |
| | | `batt_state3` int(11) NOT NULL DEFAULT '0' COMMENT '组3电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol3` float NOT NULL DEFAULT '0' COMMENT '组3输出电压', |
| | | `mod_outcurr3` float NOT NULL DEFAULT '0' COMMENT '组3输出电流', |
| | | `mod_enable4` int(11) NOT NULL DEFAULT '0' COMMENT '组4模块使能状态[0-断开 1-闭合]', |
| | | `batt_state4` int(11) NOT NULL DEFAULT '0' COMMENT '组4电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol4` float NOT NULL DEFAULT '0' COMMENT '组4输出电压', |
| | | `mod_outcurr4` float NOT NULL DEFAULT '0' COMMENT '组4输出电流', |
| | | `mod_enable5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]', |
| | | `batt_state5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]', |
| | | `mod_outvol5` float NOT NULL DEFAULT '0' COMMENT '组5输出电压', |
| | | `mod_outcurr5` float NOT NULL DEFAULT '0' COMMENT '组5输出电流', |
| | | `mod_enable6` int(11) NOT NULL DEFAULT '0' COMMENT '组6模块使能状态[0-断开 1-闭合]', |
| | | `batt_state6` int(11) NOT NULL DEFAULT '0' COMMENT '组6电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol6` float NOT NULL DEFAULT '0' COMMENT '组6输出电压', |
| | | `mod_outcurr6` float NOT NULL DEFAULT '0' COMMENT '组6输出电流', |
| | | `mod_enable7` int(11) NOT NULL DEFAULT '0' COMMENT '组7模块使能状态[0-断开 1-闭合]', |
| | | `batt_state7` int(11) NOT NULL DEFAULT '0' COMMENT '组7电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outVol7` float NOT NULL DEFAULT '0' COMMENT '组7输出电压', |
| | | `mod_outcurr7` float NOT NULL DEFAULT '0' COMMENT '组7输出电流', |
| | | `mod_enable8` int(11) NOT NULL DEFAULT '0' COMMENT '组8模块使能状态[0-断开 1-闭合]', |
| | | `batt_state8` int(11) NOT NULL DEFAULT '0' COMMENT '组8电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol8` float NOT NULL DEFAULT '0' COMMENT '组8输出电压', |
| | | `mod_outcurr8` float NOT NULL DEFAULT '0' COMMENT '组8输出电流', |
| | | `mod_enable9` int(11) NOT NULL DEFAULT '0' COMMENT '组9模块使能状态[0-断开 1-闭合]', |
| | | `batt_state9` int(11) NOT NULL DEFAULT '0' COMMENT '组9电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol9` float NOT NULL DEFAULT '0' COMMENT '组9输出电压', |
| | | `mod_outcurr9` float NOT NULL DEFAULT '0' COMMENT '组9输出电流', |
| | | `mod_enable10` int(11) NOT NULL DEFAULT '0' COMMENT '组10模块使能状态[0-断开 1-闭合]', |
| | | `batt_state10` int(11) NOT NULL DEFAULT '0' COMMENT '组10电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol10` float NOT NULL DEFAULT '0' COMMENT '组10输出电压', |
| | | `mod_outcurr10` float NOT NULL DEFAULT '0' COMMENT '组10输出电流', |
| | | PRIMARY KEY (`num`) |
| | | ) ENGINE=InnoDB DEFAULT CHARSET=utf8 COMMENT='并联BTS拓扑状态信息'; |
| | | |
| | | |
| | | V1.64 edit at date 2023-04-01 |
| | | 1.db_app_sys.tb_menu新增 |
| | | `lableEnUs` varchar(255) DEFAULT '' COMMENT '国际化英文列' |
| | |
| | | // if(rs.getBoolean("AppServer_Reinit_BattGroupData_EN") == false) {
|
| | | //System.out.println("修改数据库中的是否重载数据");
|
| | | String sql_str_1 = "UPDATE " + Sql_Mysql.AppSys_Table + " SET "
|
| | | + " AppServer_Reinit_BattGroupData_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_LD9_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_A059_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_61851_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_60870_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_FBO4815_EN = 1,"
|
| | | + " AppServer_Reinit_BattGroupData_FBO4830_EN = 1"
|
| | | + " AppServer_Reinit_BattGroupData_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_LD9_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_A059_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_61851_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_60870_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_FBO4815_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_FBO4830_EN = 1 "
|
| | | + " ,AppServer_Reinit_BattGroupData_FBO4831_EN = 1 "
|
| | | + " WHERE num > 0"
|
| | | ;
|
| | | sql.sqlMysqlExecute(sql_str_1);
|
| | |
| | | //创建电操开关遥测实时状态表 |
| | | createDEV60870_Inverter_Info(pool, recreate); |
| | | |
| | | //创建并联BTS拓扑状态信息表 |
| | | createFBS9140_Topology_State(pool, recreate); |
| | | |
| | | System.out.println(" Db_Ram_Db init end at " + Com.getDateTimeFormat(new Date(), Com.DTF_YMDhms)); |
| | | } |
| | | |
| | |
| | | " `inverterTmpAlmC` int(11) NOT NULL DEFAULT '0' COMMENT '逆变器C温度报警'," + |
| | | " PRIMARY KEY (`num`)" + |
| | | ") ENGINE=InnoDB AUTO_INCREMENT=1 DEFAULT CHARSET=utf8 COMMENT='电操开关遥信实时状态表';"; |
| | | Sql_Mysql sql = new Sql_Mysql(pool.getConn()); |
| | | try { |
| | | if(true == recreate) { |
| | | sql.sqlMysqlExecute(sql_str01); |
| | | } |
| | | sql.sqlMysqlExecute(sql_str02); |
| | | } catch (SQLException e) { |
| | | e.printStackTrace(); |
| | | } finally { |
| | | sql.close_con(); |
| | | } |
| | | } |
| | | |
| | | /** |
| | | * 创建并联BTS拓扑状态信息 |
| | | * @param pool |
| | | * @param recreate |
| | | */ |
| | | private static void createFBS9140_Topology_State(MysqlConnPool pool, boolean recreate) { |
| | | String sql_str01 = " DROP TABLE IF EXISTS "+Sql_Mysql.FBS9140_Topology_State; |
| | | String sql_str02 = "CREATE TABLE IF NOT EXISTS " + Sql_Mysql.FBS9140_Topology_State + " (" + |
| | | " `num` bigint(20) NOT NULL AUTO_INCREMENT COMMENT '主键'," + |
| | | " `dev_id` int(11) NOT NULL DEFAULT '0' COMMENT '设备id'," + |
| | | " `record_time` datetime NOT NULL DEFAULT '2000-01-01 00:00:00' COMMENT '记录时间'," + |
| | | " `grouptotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '电池组总数'," + |
| | | " `montotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '单体总数'," + |
| | | " `onlinevol` float NOT NULL DEFAULT '0' COMMENT '在线电压'," + |
| | | " `accurrrindex` int(11) NOT NULL DEFAULT '0' COMMENT '当前AC输入索引[0-#1 1-#2]'," + |
| | | " `acua_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电压'," + |
| | | " `acub_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电压'," + |
| | | " `acuc_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电压'," + |
| | | " `acia_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电流'," + |
| | | " `acib_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电流'," + |
| | | " `acic_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电流'," + |
| | | " `acua_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电压'," + |
| | | " `acub_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电压'," + |
| | | " `acuc_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电压'," + |
| | | " `acia_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电流'," + |
| | | " `acib_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电流'," + |
| | | " `acic_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电流'," + |
| | | " `mod_enable1` int(11) NOT NULL DEFAULT '0' COMMENT '组1模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state1` int(11) NOT NULL DEFAULT '0' COMMENT '组1电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol1` float NOT NULL DEFAULT '0' COMMENT '组1输出电压'," + |
| | | " `mod_outcurr1` float NOT NULL DEFAULT '0' COMMENT '组1输出电流'," + |
| | | " `mod_enable2` int(11) NOT NULL DEFAULT '0' COMMENT '组2模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state2` int(11) NOT NULL DEFAULT '0' COMMENT '组2电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol2` float NOT NULL DEFAULT '0' COMMENT '组2输出电压'," + |
| | | " `mod_outcurr2` float NOT NULL DEFAULT '0' COMMENT '组2输出电流'," + |
| | | " `mod_enable3` int(11) NOT NULL DEFAULT '0' COMMENT '组3模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state3` int(11) NOT NULL DEFAULT '0' COMMENT '组3电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol3` float NOT NULL DEFAULT '0' COMMENT '组3输出电压'," + |
| | | " `mod_outcurr3` float NOT NULL DEFAULT '0' COMMENT '组3输出电流'," + |
| | | " `mod_enable4` int(11) NOT NULL DEFAULT '0' COMMENT '组4模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state4` int(11) NOT NULL DEFAULT '0' COMMENT '组4电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol4` float NOT NULL DEFAULT '0' COMMENT '组4输出电压'," + |
| | | " `mod_outcurr4` float NOT NULL DEFAULT '0' COMMENT '组4输出电流'," + |
| | | " `mod_enable5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]'," + |
| | | " `mod_outvol5` float NOT NULL DEFAULT '0' COMMENT '组5输出电压'," + |
| | | " `mod_outcurr5` float NOT NULL DEFAULT '0' COMMENT '组5输出电流'," + |
| | | " `mod_enable6` int(11) NOT NULL DEFAULT '0' COMMENT '组6模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state6` int(11) NOT NULL DEFAULT '0' COMMENT '组6电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol6` float NOT NULL DEFAULT '0' COMMENT '组6输出电压'," + |
| | | " `mod_outcurr6` float NOT NULL DEFAULT '0' COMMENT '组6输出电流'," + |
| | | " `mod_enable7` int(11) NOT NULL DEFAULT '0' COMMENT '组7模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state7` int(11) NOT NULL DEFAULT '0' COMMENT '组7电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outVol7` float NOT NULL DEFAULT '0' COMMENT '组7输出电压'," + |
| | | " `mod_outcurr7` float NOT NULL DEFAULT '0' COMMENT '组7输出电流'," + |
| | | " `mod_enable8` int(11) NOT NULL DEFAULT '0' COMMENT '组8模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state8` int(11) NOT NULL DEFAULT '0' COMMENT '组8电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol8` float NOT NULL DEFAULT '0' COMMENT '组8输出电压'," + |
| | | " `mod_outcurr8` float NOT NULL DEFAULT '0' COMMENT '组8输出电流'," + |
| | | " `mod_enable9` int(11) NOT NULL DEFAULT '0' COMMENT '组9模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state9` int(11) NOT NULL DEFAULT '0' COMMENT '组9电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol9` float NOT NULL DEFAULT '0' COMMENT '组9输出电压'," + |
| | | " `mod_outcurr9` float NOT NULL DEFAULT '0' COMMENT '组9输出电流'," + |
| | | " `mod_enable10` int(11) NOT NULL DEFAULT '0' COMMENT '组10模块使能状态[0-断开 1-闭合]'," + |
| | | " `batt_state10` int(11) NOT NULL DEFAULT '0' COMMENT '组10电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]'," + |
| | | " `mod_outvol10` float NOT NULL DEFAULT '0' COMMENT '组10输出电压'," + |
| | | " `mod_outcurr10` float NOT NULL DEFAULT '0' COMMENT '组10输出电流'," + |
| | | " PRIMARY KEY (`num`)" + |
| | | ") ENGINE=InnoDB DEFAULT CHARSET=utf8 COMMENT='并联BTS拓扑状态信息'; "; |
| | | Sql_Mysql sql = new Sql_Mysql(pool.getConn()); |
| | | try { |
| | | if(true == recreate) { |
| | |
| | | + " AND table_name='tb_fbs9100_state'" |
| | | + " AND column_name='dev_version'"); |
| | | if(true == res.next()) { |
| | | sql.sqlMysqlExecute("ALTER TABLE " +Sql_Mysql.FBS9100State_Table + " MODIFY COLUMN dev_version varchar(64) NOT NULL DEFAULT '';"); |
| | | sql.sqlMysqlExecute("ALTER TABLE " +Sql_Mysql.FBS9100State_Table + " MODIFY COLUMN dev_version varchar(255) NOT NULL DEFAULT '';"); |
| | | } |
| | | |
| | | //添加设备温度列 |
| | |
| | | if(false == res.next()) { |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11024', 'WEB_PLATFORM_SERVER', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'WEB_PLATFORM_SERVER', '1', 'v1.100', '蓄电池WEB平台服务', '300');"); |
| | | } |
| | | //FBO4815通信线程 |
| | | res = sql.sqlMysqlQuery("SELECT ProcessName FROM "+ Sql_Mysql.ProcessSurvey_Table + " WHERE ProcessId = 11025"); |
| | | if(false == res.next()) { |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11025', 'BMS_BATT_FBC_4831NT', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_BATT_FBC_4831NT', '2', 'v1.100', 'FBC4831通信线程', '300');"); |
| | | } |
| | | } catch (SQLException e) { |
| | | e.printStackTrace(); |
| | | } finally { |
| | |
| | | |
| | | public final static String DEV60870_Inverter_State = DB_RamDB + ".tb_dev_60870_inverter_state"; //电操开关遥信实时状态表 |
| | | public final static String DEV60870_Inverter_Info = DB_RamDB + ".tb_dev_60870_inverter_info"; //电操开关遥测实时状态表 |
| | | public final static String FBS9140_Topology_State = DB_RamDB + ".tb_fbs9140_topology_state"; //并联BTS拓扑状态信息 |
| | | |
| | | |
| | | /**************************** db_user数据库 ***************************************************/ |
| | |
| | | 蓄电池监控平台建表程序 |
| | | |
| | | V1.65 edit at date 2024-04-04 |
| | | 1.db_ram_db.tb_fbs9100_state表扩展版本号长度,FBS300版本号超出原本长度,扩展设备版本号字段 |
| | | `dev_version` varchar(255) NOT NULL DEFAULT '', |
| | | 2.后台线程管理新增 FBC4831线程 - ProcessId = 11025 |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11025', 'BMS_BATT_FBC_4831NT', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_BATT_FBC_4831NT', '2', 'v1.100', 'FBC4831通信线程', '300');"); |
| | | 3.创建并联BTS拓扑状态信息表 'db_ram_db.tb_fbs9140_topology_state' |
| | | CREATE TABLE `tb_fbs9140_topology_state` ( |
| | | `num` bigint(20) NOT NULL AUTO_INCREMENT COMMENT '主键', |
| | | `dev_id` int(11) NOT NULL DEFAULT '0' COMMENT '设备id', |
| | | `record_time` datetime NOT NULL DEFAULT '2000-01-01 00:00:00' COMMENT '记录时间', |
| | | `grouptotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '电池组总数', |
| | | `montotalnum` int(11) NOT NULL DEFAULT '0' COMMENT '单体总数', |
| | | `onlinevol` float NOT NULL DEFAULT '0' COMMENT '在线电压', |
| | | `accurrrindex` int(11) NOT NULL DEFAULT '0' COMMENT '当前AC输入索引[0-#1 1-#2]', |
| | | `acua_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电压', |
| | | `acub_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电压', |
| | | `acuc_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电压', |
| | | `acia_1` float NOT NULL DEFAULT '0' COMMENT '#1交流A相电流', |
| | | `acib_1` float NOT NULL DEFAULT '0' COMMENT '#1交流B相电流', |
| | | `acic_1` float NOT NULL DEFAULT '0' COMMENT '#1交流C相电流', |
| | | `acua_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电压', |
| | | `acub_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电压', |
| | | `acuc_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电压', |
| | | `acia_2` float NOT NULL DEFAULT '0' COMMENT '#2交流A相电流', |
| | | `acib_2` float NOT NULL DEFAULT '0' COMMENT '#2交流B相电流', |
| | | `acic_2` float NOT NULL DEFAULT '0' COMMENT '#2交流C相电流', |
| | | `mod_enable1` int(11) NOT NULL DEFAULT '0' COMMENT '组1模块使能状态[0-断开 1-闭合]', |
| | | `batt_state1` int(11) NOT NULL DEFAULT '0' COMMENT '组1电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol1` float NOT NULL DEFAULT '0' COMMENT '组1输出电压', |
| | | `mod_outcurr1` float NOT NULL DEFAULT '0' COMMENT '组1输出电流', |
| | | `mod_enable2` int(11) NOT NULL DEFAULT '0' COMMENT '组2模块使能状态[0-断开 1-闭合]', |
| | | `batt_state2` int(11) NOT NULL DEFAULT '0' COMMENT '组2电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol2` float NOT NULL DEFAULT '0' COMMENT '组2输出电压', |
| | | `mod_outcurr2` float NOT NULL DEFAULT '0' COMMENT '组2输出电流', |
| | | `mod_enable3` int(11) NOT NULL DEFAULT '0' COMMENT '组3模块使能状态[0-断开 1-闭合]', |
| | | `batt_state3` int(11) NOT NULL DEFAULT '0' COMMENT '组3电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol3` float NOT NULL DEFAULT '0' COMMENT '组3输出电压', |
| | | `mod_outcurr3` float NOT NULL DEFAULT '0' COMMENT '组3输出电流', |
| | | `mod_enable4` int(11) NOT NULL DEFAULT '0' COMMENT '组4模块使能状态[0-断开 1-闭合]', |
| | | `batt_state4` int(11) NOT NULL DEFAULT '0' COMMENT '组4电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol4` float NOT NULL DEFAULT '0' COMMENT '组4输出电压', |
| | | `mod_outcurr4` float NOT NULL DEFAULT '0' COMMENT '组4输出电流', |
| | | `mod_enable5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]', |
| | | `batt_state5` int(11) NOT NULL DEFAULT '0' COMMENT '组5模块使能状态[0-断开 1-闭合]', |
| | | `mod_outvol5` float NOT NULL DEFAULT '0' COMMENT '组5输出电压', |
| | | `mod_outcurr5` float NOT NULL DEFAULT '0' COMMENT '组5输出电流', |
| | | `mod_enable6` int(11) NOT NULL DEFAULT '0' COMMENT '组6模块使能状态[0-断开 1-闭合]', |
| | | `batt_state6` int(11) NOT NULL DEFAULT '0' COMMENT '组6电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol6` float NOT NULL DEFAULT '0' COMMENT '组6输出电压', |
| | | `mod_outcurr6` float NOT NULL DEFAULT '0' COMMENT '组6输出电流', |
| | | `mod_enable7` int(11) NOT NULL DEFAULT '0' COMMENT '组7模块使能状态[0-断开 1-闭合]', |
| | | `batt_state7` int(11) NOT NULL DEFAULT '0' COMMENT '组7电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outVol7` float NOT NULL DEFAULT '0' COMMENT '组7输出电压', |
| | | `mod_outcurr7` float NOT NULL DEFAULT '0' COMMENT '组7输出电流', |
| | | `mod_enable8` int(11) NOT NULL DEFAULT '0' COMMENT '组8模块使能状态[0-断开 1-闭合]', |
| | | `batt_state8` int(11) NOT NULL DEFAULT '0' COMMENT '组8电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol8` float NOT NULL DEFAULT '0' COMMENT '组8输出电压', |
| | | `mod_outcurr8` float NOT NULL DEFAULT '0' COMMENT '组8输出电流', |
| | | `mod_enable9` int(11) NOT NULL DEFAULT '0' COMMENT '组9模块使能状态[0-断开 1-闭合]', |
| | | `batt_state9` int(11) NOT NULL DEFAULT '0' COMMENT '组9电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol9` float NOT NULL DEFAULT '0' COMMENT '组9输出电压', |
| | | `mod_outcurr9` float NOT NULL DEFAULT '0' COMMENT '组9输出电流', |
| | | `mod_enable10` int(11) NOT NULL DEFAULT '0' COMMENT '组10模块使能状态[0-断开 1-闭合]', |
| | | `batt_state10` int(11) NOT NULL DEFAULT '0' COMMENT '组10电池状态[0:浮充 1:均充 2:供电 3:核容 4:尾充]', |
| | | `mod_outvol10` float NOT NULL DEFAULT '0' COMMENT '组10输出电压', |
| | | `mod_outcurr10` float NOT NULL DEFAULT '0' COMMENT '组10输出电流', |
| | | PRIMARY KEY (`num`) |
| | | ) ENGINE=InnoDB DEFAULT CHARSET=utf8 COMMENT='并联BTS拓扑状态信息'; |
| | | |
| | | |
| | | V1.64 edit at date 2023-04-01 |
| | | 1.db_app_sys.tb_menu新增 |
| | | `lableEnUs` varchar(255) DEFAULT '' COMMENT '国际化英文列' |
| | |
| | | /**************************************************************************/ |
| | | /**************************************************************************/ |
| | | public final static boolean app_debug = false; |
| | | public final static float m_VersionNum = (float) 1.64; |
| | | public final static float m_VersionNum = (float) 1.65; |
| | | public final static String m_Version = "Welcome To Use BTS DB BUILDER V" + m_VersionNum + " RC_20180908"; |
| | | /**************************************************************************/ |
| | | /**************************************************************************/ |