蓄电池监控管理平台数据库初始化程序
Administrator
2022-12-26 8741892996fd73dfe581f64a2f3842f4c56d19a8
3.web_site.tb_peak_statistics 新增字段
`electric_fromelec` float NOT NULL DEFAULT '0' COMMENT '电能表展示的用电量'

4.web_site.tb_process_survey 新增线程数据 - FBO4830NT通信线程
4个文件已修改
10 ■■■■■ 已修改文件
BattMonitor_DB_Builder/bin/com/version_inf/version_inf.txt 2 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_DB_Builder/src/com/battdata_rt/BattData_RT_RamDB_Thread_SQL.java 1 ●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_DB_Builder/src/com/database_util/DB_web_site.java 5 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_DB_Builder/src/com/version_inf/version_inf.txt 2 ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史
BattMonitor_DB_Builder/bin/com/version_inf/version_inf.txt
@@ -21,6 +21,8 @@
          
      3.web_site.tb_peak_statistics 新增字段
          `electric_fromelec` float NOT NULL DEFAULT '0' COMMENT '电能表展示的用电量'
      4.web_site.tb_process_survey 新增线程数据  - FBO4830NT通信线程
BattMonitor_DB_Builder/src/com/battdata_rt/BattData_RT_RamDB_Thread_SQL.java
@@ -447,6 +447,7 @@
                                + " AppServer_Reinit_BattGroupData_LD9_EN = 1,"
                                + " AppServer_Reinit_BattGroupData_A059_EN = 1,"
                                + " AppServer_Reinit_BattGroupData_61851_EN = 1"
                                + " AppServer_Reinit_BattGroupData_FBO4830_EN = 1"
                                + " WHERE num > 0"
                                ;
                        sql.sqlMysqlExecute(sql_str_1);
BattMonitor_DB_Builder/src/com/database_util/DB_web_site.java
@@ -4076,6 +4076,11 @@
            if(false == res.next()) {
                sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11020', 'BMS_REMOTE_RESTART_DEVICE',     '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_REMOTE_RESTART_DEVICE', '2', 'v1.100', '远程重启装置通信线程', '300');");
            }
            //远程重启装置线程
            res = sql.sqlMysqlQuery("SELECT ProcessName FROM "+ Sql_Mysql.ProcessSurvey_Table + " WHERE ProcessId = 11021");
            if(false == res.next()) {
                sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11021', 'BMS_BATT_FBO_4830NT',     '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_BATT_FBO_4830NT', '2', 'v1.100', 'FBO4830NT通信线程', '300');");
            }
        } catch (SQLException e) {
            e.printStackTrace();
        } finally {
BattMonitor_DB_Builder/src/com/version_inf/version_inf.txt
@@ -21,6 +21,8 @@
          
      3.web_site.tb_peak_statistics 新增字段
          `electric_fromelec` float NOT NULL DEFAULT '0' COMMENT '电能表展示的用电量'
      4.web_site.tb_process_survey 新增线程数据  - FBO4830NT通信线程