6.线程监控中新增 '通信电源核容一体机通信线程'
通信电源核容一体机通信线程-11034
| | |
| | | `label_cfg` varchar(255) NOT NULL DEFAULT '' COMMENT '实时监控标签配置(空字符串所有都选中)' |
| | | 5.表'db_ram_db.tb_batt_rtstate'新增字段'control_fail_type' --启动失败原因 |
| | | `control_fail_type` int(11) NOT NULL DEFAULT '0' COMMENT '启动失败原因\r\n6186-[\r\n0x00-成功\r\n0x03-内部通信故障\r\n0x04-系统存在告警\r\n0x05-系统测试中\r\n0x06-输入电压过高\r\n0x07-输入电压过低\r\n0X08-负载功率太小\r\n0x09-两段直流母线压差大\r\n0x0A-两段电池组压差大\r\n0x0B-远程闭锁状态\r\n0x0C-急停状态\r\n0x0D-切换开关粘连或电源状态异常\r\n0x0E-启动频繁\r\n0x0F-系统正在内阻测试\r\n0xFF-未知\r\n]', |
| | | |
| | | 6.线程监控中新增 '通信电源核容一体机通信线程' |
| | | 通信电源核容一体机通信线程-11034 |
| | | |
| | | V2.08 edit at date 2024-10-05 |
| | | 1.新增动环相关配置库表 |
| | |
| | | sql.sqlMysqlExecute("ALTER TABLE " + Sql_Mysql.BattRtState_Table |
| | | + " ADD COLUMN `control_fail_type` int(11) NOT NULL DEFAULT '0' COMMENT '启动失败原因\\r\\n6186-[\\r\\n0x00-成功\\r\\n0x03-内部通信故障\\r\\n0x04-系统存在告警\\r\\n0x05-系统测试中\\r\\n0x06-输入电压过高\\r\\n0x07-输入电压过低\\r\\n0X08-负载功率太小\\r\\n0x09-两段直流母线压差大\\r\\n0x0A-两段电池组压差大\\r\\n0x0B-远程闭锁状态\\r\\n0x0C-急停状态\\r\\n0x0D-切换开关粘连或电源状态异常\\r\\n0x0E-启动频繁\\r\\n0x0F-系统正在内阻测试\\r\\n0xFF-未知\\r\\n]';"); |
| | | } |
| | | //新增字段'last_captest_stop_type' --上一次核容终止原因 |
| | | res = sql.sqlMysqlQuery("SELECT * FROM information_schema.columns" |
| | | + " WHERE table_schema='db_ram_db'" |
| | | + " AND table_name='tb_batt_rtstate'" |
| | | + " AND column_name='last_captest_stop_type'"); |
| | | if(false == res.next()) { |
| | | sql.sqlMysqlExecute("ALTER TABLE " + Sql_Mysql.BattRtState_Table |
| | | + " ADD COLUMN `last_captest_stop_type` int(11) NOT NULL DEFAULT '0' COMMENT '上一次核容终止原因';"); |
| | | } |
| | | } catch (SQLException e) { |
| | | e.printStackTrace(); |
| | | } finally { |
| | |
| | | if(false == res.next()) { |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11033', 'BMS_FBS6184_NIBIAN', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_FBS6184_NIBIAN', '2', 'v1.100', '全功能逆变假负载6184通信线程', '300');"); |
| | | } |
| | | //通信电源核容一体机通信线程-11034 |
| | | res = sql.sqlMysqlQuery("SELECT ProcessName FROM "+ Sql_Mysql.ProcessSurvey_Table + " WHERE ProcessId = 11034"); |
| | | if(false == res.next()) { |
| | | sql.sqlMysqlExecute(" INSERT INTO " + Sql_Mysql.ProcessSurvey_Table + "(ProcessId,ProcessName,ProcessTime,Process_starttime,ServerName,ServerFlag,ProcessVersion,note,OutTime) VALUES ('11034', 'BMS_BTS61590_MONITOR', '1970-01-01 00:00:00', '1970-01-01 00:00:00', 'BMS_BTS61590_MONITOR', '2', 'v1.100', '通信电源核容一体机通信线程', '300');"); |
| | | } |
| | | } catch (SQLException e) { |
| | | e.printStackTrace(); |
| | | } finally { |
| | |
| | | `label_cfg` varchar(255) NOT NULL DEFAULT '' COMMENT '实时监控标签配置(空字符串所有都选中)' |
| | | 5.表'db_ram_db.tb_batt_rtstate'新增字段'control_fail_type' --启动失败原因 |
| | | `control_fail_type` int(11) NOT NULL DEFAULT '0' COMMENT '启动失败原因\r\n6186-[\r\n0x00-成功\r\n0x03-内部通信故障\r\n0x04-系统存在告警\r\n0x05-系统测试中\r\n0x06-输入电压过高\r\n0x07-输入电压过低\r\n0X08-负载功率太小\r\n0x09-两段直流母线压差大\r\n0x0A-两段电池组压差大\r\n0x0B-远程闭锁状态\r\n0x0C-急停状态\r\n0x0D-切换开关粘连或电源状态异常\r\n0x0E-启动频繁\r\n0x0F-系统正在内阻测试\r\n0xFF-未知\r\n]', |
| | | |
| | | 6.线程监控中新增 '通信电源核容一体机通信线程' |
| | | 通信电源核容一体机通信线程-11034 |
| | | |
| | | V2.08 edit at date 2024-10-05 |
| | | 1.新增动环相关配置库表 |