BattMonitor_DB_Builder/bin/com/version_inf/version_inf.txt | ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史 | |
BattMonitor_DB_Builder/src/com/battdata_rt/BattData_RT_RamDB_Thread_SQL.java | ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史 | |
BattMonitor_DB_Builder/src/com/sql/Sql_Mysql.java | ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史 | |
BattMonitor_DB_Builder/src/com/version_inf/version_inf.txt | ●●●●● 补丁 | 查看 | 原始文档 | blame | 历史 |
BattMonitor_DB_Builder/bin/com/version_inf/version_inf.txt
@@ -22,8 +22,10 @@ 3.web_site.tb_peak_statistics 新增字段 `electric_fromelec` float NOT NULL DEFAULT '0' COMMENT '电能表展示的用电量' 4.web_site.tb_process_survey 新增线程数据 - FBO4830NT通信线程 4.web_site.tb_process_survey 新增线程数据 - FBO4830NT通信线程 - 11021 5.db_app_sys.tb_app_sys 新增字段 `AppServer_Reinit_BattGroupData_FBO4830_EN` tinyint(1) NOT NULL DEFAULT '0', BattMonitor_DB_Builder/src/com/battdata_rt/BattData_RT_RamDB_Thread_SQL.java
@@ -446,7 +446,7 @@ + " AppServer_Reinit_BattGroupData_EN = 1," + " AppServer_Reinit_BattGroupData_LD9_EN = 1," + " AppServer_Reinit_BattGroupData_A059_EN = 1," + " AppServer_Reinit_BattGroupData_61851_EN = 1" + " AppServer_Reinit_BattGroupData_61851_EN = 1," + " AppServer_Reinit_BattGroupData_FBO4830_EN = 1" + " WHERE num > 0" ; BattMonitor_DB_Builder/src/com/sql/Sql_Mysql.java
@@ -717,6 +717,16 @@ + " ADD COLUMN `AppServer_Reinit_BattGroupData_LD9_EN` BOOLEAN NOT NULL DEFAULT false" + " AFTER `AppServer_Reinit_BattGroupData_EN`"); } /**************************** db_app_sys 表中添加 AppServer_Reinit_BattGroupData_FBO4830_EN 列(用于4830主程序动态加载设备参数) *******************************************/ res0 = sqlMysqlQuery("SELECT * FROM information_schema.columns" + " WHERE table_schema='db_app_sys'" + " AND table_name='tb_app_sys'" + " AND column_name='AppServer_Reinit_BattGroupData_FBO4830_EN'"); if(false == res0.next()) { sqlMysqlExecute("ALTER TABLE " + AppSys_Table + " ADD COLUMN `AppServer_Reinit_BattGroupData_FBO4830_EN` BOOLEAN NOT NULL DEFAULT false" + " AFTER `AppServer_Reinit_BattGroupData_LD9_EN`"); } //---------------------------------------------------------------------------------------------// sqlMysqlExecute(table_1); BattMonitor_DB_Builder/src/com/version_inf/version_inf.txt
@@ -22,8 +22,10 @@ 3.web_site.tb_peak_statistics 新增字段 `electric_fromelec` float NOT NULL DEFAULT '0' COMMENT '电能表展示的用电量' 4.web_site.tb_process_survey 新增线程数据 - FBO4830NT通信线程 4.web_site.tb_process_survey 新增线程数据 - FBO4830NT通信线程 - 11021 5.db_app_sys.tb_app_sys 新增字段 `AppServer_Reinit_BattGroupData_FBO4830_EN` tinyint(1) NOT NULL DEFAULT '0',