package com.whyc.pojo;
|
|
import com.baomidou.mybatisplus.annotation.IdType;
|
import com.baomidou.mybatisplus.annotation.TableField;
|
import com.baomidou.mybatisplus.annotation.TableId;
|
import com.baomidou.mybatisplus.annotation.TableName;
|
import com.fasterxml.jackson.annotation.JsonFormat;
|
import io.swagger.annotations.ApiModel;
|
import io.swagger.annotations.ApiModelProperty;
|
import lombok.Data;
|
import lombok.EqualsAndHashCode;
|
import lombok.experimental.Accessors;
|
|
import java.io.Serializable;
|
import java.util.Date;
|
|
|
@Data
|
@EqualsAndHashCode(callSuper = false)
|
@Accessors(chain = true)
|
@TableName(schema = "db_power",value ="pwrdev_acdcdata")
|
@ApiModel(value="电源实时数据", description="")
|
public class PwrdevAcdcdata implements Serializable {
|
|
private static final long serialVersionUID = 1L;
|
|
@TableId(value = "num", type = IdType.AUTO)
|
private int num;
|
|
@TableField("pinf_id")
|
private int pinfId;
|
|
@JsonFormat(pattern="yyyy-MM-dd HH:mm:ss")
|
private Date recordTime;
|
|
@ApiModelProperty("第1路交流A相输入电压")
|
@TableField("ac_in1_vol_a")
|
private Float acIn1VolA;
|
@ApiModelProperty("第1路交流B相输入电压")
|
@TableField("ac_in1_vol_b")
|
private Float acIn1VolB;
|
@ApiModelProperty("第1路交流C相输入电压")
|
@TableField("ac_in1_vol_c")
|
private Float acIn1VolC;
|
@ApiModelProperty("第2路交流A相输入电压")
|
@TableField("ac_in2_vol_a")
|
private Float acIn2VolA;
|
@ApiModelProperty("第2路交流B相输入电压")
|
@TableField("ac_in2_vol_b")
|
private Float acIn2VolB;
|
@ApiModelProperty("第2路交流C相输入电压")
|
@TableField("ac_in2_vol_c")
|
private Float acIn2VolC;
|
@ApiModelProperty("交流A相输出电压")
|
@TableField("ac_out_vol_a")
|
private Float acOutVolA;
|
@ApiModelProperty("交流B相输出电压")
|
@TableField("ac_out_vol_b")
|
private Float acOutVolB;
|
@ApiModelProperty("交流C相输出电压")
|
@TableField("ac_out_vol_c")
|
private Float acOutVolC;
|
@ApiModelProperty("交流A相输出电流")
|
@TableField("ac_out_curr_a")
|
private Float acOutCurrA;
|
@ApiModelProperty("交流B相输出电流")
|
@TableField("ac_out_curr_b")
|
private Float acOutCurrB;
|
@ApiModelProperty("交流C相输出电流")
|
@TableField("ac_out_curr_c")
|
private Float acOutCurrC;
|
@ApiModelProperty("直流输出电压")
|
@TableField("dc_out_vol")
|
private Float dcOutVol;
|
@ApiModelProperty("直流输出电流")
|
@TableField("dc_out_curr")
|
private Float dcOutCurr;
|
|
@ApiModelProperty("蓄电池组1充电电压")
|
@TableField("battgroup1_vol")
|
private Float battgroup1Vol;
|
|
@ApiModelProperty("蓄电池组1充电电流")
|
@TableField("battgroup1_curr")
|
private Float battgroup1Curr;
|
|
@ApiModelProperty("蓄电池组2充电电压")
|
@TableField("battgroup2_vol")
|
private Float battgroup2Vol;
|
|
@ApiModelProperty("蓄电池组1充电电流")
|
@TableField("battgroup2_curr")
|
private Float battgroup2Curr;
|
|
@ApiModelProperty("交流配电柜温度")
|
@TableField("temprature")
|
private Float temprature;
|
|
@ApiModelProperty("模块输出电压")
|
@TableField("m_outputvol")
|
private Float mOutputvol;
|
|
@TableField("m1_out_curr")
|
private Float m1OutCurr;
|
|
@TableField("m2_out_curr")
|
private Float m2OutCurr;
|
|
@TableField("m3_out_curr")
|
private Float m3OutCurr;
|
|
@TableField("m4_out_curr")
|
private Float m4OutCurr;
|
|
@TableField("m5_out_curr")
|
private Float m51OutCurr;
|
|
@TableField("m6_out_curr")
|
private Float m6OutCurr;
|
|
@TableField("m7_out_curr")
|
private Float m7OutCurr;
|
|
@TableField("m8_out_curr")
|
private Float m8OutCurr;
|
|
@TableField("m9_out_curr")
|
private Float m9OutCurr;
|
|
@TableField("m10_out_curr")
|
private Float m10OutCurr;
|
|
@TableField("m11_out_curr")
|
private Float m11OutCurr;
|
|
@TableField("m12_outCurr")
|
private Float m12OutCurr;
|
|
@TableField("m13_out_curr")
|
private Float m13OutCurr;
|
|
@TableField("m14_out_curr")
|
private Float m14OutCurr;
|
|
@TableField("m15_out_curr")
|
private Float m15OutCurr;
|
|
@TableField("m16_out_curr")
|
private Float m16OutCurr;
|
|
@TableField("is_ac_in1_over_vol_a")
|
private Integer isAcIn1OverVolA;
|
|
@TableField("is_ac_in1_under_vol_a")
|
private Integer isAcIn1UnderVolA;
|
|
@TableField("is_ac_in1_less_a")
|
private Integer isAcIn1LessA;
|
|
@TableField("is_ac_in1_over_vol_b")
|
private Integer isAcIn1OverVolB;
|
|
@TableField("is_ac_in1_under_vol_b")
|
private Integer isAcIn1UnderVolB;
|
|
@TableField("is_ac_in1_less_b")
|
private Integer isAcIn1LessB;
|
|
@TableField("is_ac_in1_over_vol_c")
|
private Integer isAcIn1OverVolC;
|
|
@TableField("is_ac_in1_under_vol_c")
|
private Integer isAcIn1UnderVolC;
|
|
@TableField("is_ac_in1_less_c")
|
private Integer isAcIn1LessC;
|
|
@TableField("is_ac_in1_thunder_err")
|
private Integer isAcIn1ThunderErr;
|
@ApiModelProperty("交流输入1停电")
|
@TableField("is_ac_in1_powerdown")
|
private Integer isAcIn1Powerdown;
|
@ApiModelProperty("第2路交流A相过压")
|
@TableField("is_ac_in2_over_vol_a")
|
private Integer isAcIn2OverVolA;
|
@ApiModelProperty("第2路交流A相欠压")
|
@TableField("is_ac_in2_under_vol_a")
|
private Integer isAcIn2UnderVolA;
|
@ApiModelProperty("第2路交流A相缺相")
|
@TableField("is_ac_in2_less_a")
|
private Integer isAcIn2LessA;
|
|
@TableField("is_ac_in2_over_vol_b")
|
private Integer isAcIn2OverVolB;
|
|
@TableField("is_ac_in2_under_vol_b")
|
private Integer isAcIn2UnderVolB;
|
|
@TableField("is_ac_in2_less_b")
|
private Integer isAcIn2LessB;
|
|
@TableField("is_ac_in2_over_vol_c")
|
private Integer isAcIn2OverVolC;
|
|
@TableField("is_ac_in2_under_vol_c")
|
private Integer isAcIn2UnderVolC;
|
|
@TableField("is_ac_in2_less_c")
|
private Integer isAcIn2LessC;
|
@ApiModelProperty("交流输入2防雷器故障")
|
@TableField("is_ac_in2_thunder_err")
|
private Integer isAcIn2ThunderErr;
|
|
@TableField("is_ac_in2_powerdown")
|
private Integer isAcIn2Powerdown;
|
@ApiModelProperty("监控单元故障")
|
@TableField("is_ac_in_monitorerr")
|
private Integer isAcInMonitorerr;
|
@ApiModelProperty("直流输出过压")
|
@TableField("is_dc_out_over_vol")
|
private Integer isDcOutOverVol;
|
@ApiModelProperty("直流输出欠压")
|
@TableField("is_dc_out_under_vol")
|
private Integer isDcOutUnderVol;
|
@ApiModelProperty("电池组下电保护告警")
|
@TableField("is_battgroup_down")
|
private Integer isBattgroupDown;
|
@ApiModelProperty("均/浮充状态")
|
@TableField("is_jun_charge")
|
private Integer isJunCharge;
|
|
|
@ApiModelProperty("模块1故障")
|
@TableField("is_acdc_mod1_err")
|
private Integer isAcdcMod1Err;
|
@ApiModelProperty("模块1开/关机")
|
@TableField("is_acdc_mod1_off")
|
private Integer isAcdcMod1Off;
|
|
@ApiModelProperty("模块2故障")
|
@TableField("is_acdc_mod2_err")
|
private Integer isAcdcMod2Err;
|
@ApiModelProperty("模块2开/关机")
|
@TableField("is_acdc_mod2_off")
|
private Integer isAcdcMod2Off;
|
|
@ApiModelProperty("模块3故障")
|
@TableField("is_acdc_mod3_err")
|
private Integer isAcdcMod3Err;
|
@ApiModelProperty("模块3开/关机")
|
@TableField("is_acdc_mod3_off")
|
private Integer isAcdcMod3Off;
|
|
@ApiModelProperty("模块4故障")
|
@TableField("is_acdc_mod4_err")
|
private Integer isAcdcMod4Err;
|
@ApiModelProperty("模块4开/关机")
|
@TableField("is_acdc_mod4_off")
|
private Integer isAcdcMod4Off;
|
|
@ApiModelProperty("模块5故障")
|
@TableField("is_acdc_mod5_err")
|
private Integer isAcdcMod5Err;
|
@ApiModelProperty("模块5开/关机")
|
@TableField("is_acdc_mod5_off")
|
private Integer isAcdcMod5Off;
|
|
@ApiModelProperty("模块6故障")
|
@TableField("is_acdc_mod6_err")
|
private Integer isAcdcMod6Err;
|
@ApiModelProperty("模块6开/关机")
|
@TableField("is_acdc_mod6_off")
|
private Integer isAcdcMod6Off;
|
|
@ApiModelProperty("模块7故障")
|
@TableField("is_acdc_mod7_err")
|
private Integer isAcdcMod7Err;
|
@ApiModelProperty("模块7开/关机")
|
@TableField("is_acdc_mod7_off")
|
private Integer isAcdcMod7Off;
|
|
@ApiModelProperty("模块8故障")
|
@TableField("is_acdc_mod8_err")
|
private Integer isAcdcMod8Err;
|
@ApiModelProperty("模块8开/关机")
|
@TableField("is_acdc_mod8_off")
|
private Integer isAcdcMod8Off;
|
|
@ApiModelProperty("模块9故障")
|
@TableField("is_acdc_mod9_err")
|
private Integer isAcdcMod9Err;
|
@ApiModelProperty("模块9开/关机")
|
@TableField("is_acdc_mod9_off")
|
private Integer isAcdcMod9Off;
|
|
@ApiModelProperty("模块10故障")
|
@TableField("is_acdc_mod10_err")
|
private Integer isAcdcMod10Err;
|
@ApiModelProperty("模块10开/关机")
|
@TableField("is_acdc_mod10_off")
|
private Integer isAcdcMod10Off;
|
|
@ApiModelProperty("模块11故障")
|
@TableField("is_acdc_mod11_err")
|
private Integer isAcdcMod11Err;
|
@ApiModelProperty("模块11开/关机")
|
@TableField("is_acdc_mod11_off")
|
private Integer isAcdcMod11Off;
|
|
@ApiModelProperty("模块12故障")
|
@TableField("is_acdc_mod12_err")
|
private Integer isAcdcMod12Err;
|
@ApiModelProperty("模块12开/关机")
|
@TableField("is_acdc_mod12_off")
|
private Integer isAcdcMod12Off;
|
|
@ApiModelProperty("模块13故障")
|
@TableField("is_acdc_mod13_err")
|
private Integer isAcdcMod13Err;
|
@ApiModelProperty("模块13开/关机")
|
@TableField("is_acdc_mod13_off")
|
private Integer isAcdcMod13Off;
|
|
@ApiModelProperty("模块14故障")
|
@TableField("is_acdc_mod14_err")
|
private Integer isAcdcMod14Err;
|
@ApiModelProperty("模块14开/关机")
|
@TableField("is_acdc_mod14_off")
|
private Integer isAcdcMod14Off;
|
|
@ApiModelProperty("模块15故障")
|
@TableField("is_acdc_mod15_err")
|
private Integer isAcdcMod15Err;
|
@ApiModelProperty("模块15开/关机")
|
@TableField("is_acdc_mod15_off")
|
private Integer isAcdcMod15Off;
|
|
@ApiModelProperty("模块16故障")
|
@TableField("is_acdc_mod16_err")
|
private Integer isAcdcMod16Err;
|
@ApiModelProperty("模块16开/关机")
|
@TableField("is_acdc_mod16_off")
|
private Integer isAcdcMod16Off;
|
|
@TableField("is_ac_in1_trip")
|
private Integer isAcIn1Trip;
|
@ApiModelProperty("第2路交流输入开关跳闸")
|
@TableField("is_ac_in2_trip")
|
private Integer isAcIn2Trip;
|
@ApiModelProperty("负载熔丝状态")
|
@TableField("is_loader_fuse")
|
private Integer isLoaderFuse;
|
|
@ApiModelProperty("电池组1熔丝告警")
|
@TableField("is_battgroup1_fuse")
|
private Integer isBattgroup1Fuse;
|
@ApiModelProperty("电池组2熔丝告警")
|
@TableField("is_battgroup2_fuse")
|
private Integer isBattgroup2Fuse;
|
@ApiModelProperty("高频开关电源柜总告警")
|
@TableField("is_total_alarm")
|
private Integer isTotalAlarm;
|
|
@ApiModelProperty("第1路交流A相输入电流")
|
@TableField("ac_in1_curr_a")
|
private Float acIn1CurrA;
|
|
@TableField("ac_in1_curr_b")
|
private Float acIn1CurrB;
|
|
@TableField("ac_in1_curr_c")
|
private Float acIn1CurrC;
|
|
@ApiModelProperty("负载电流")
|
@TableField("loader_curr")
|
private Float loaderCurr;
|
|
@TableField("battgroup1_ah")
|
private Float battgroup1Ah;
|
|
@TableField("battgroup1_temp")
|
private Float battgroup1Temp;
|
|
@TableField("battgroup2_ah")
|
private Float battgroup2Ah;
|
|
@TableField("battgroup2_temp")
|
private Float battgroup2Temp;
|
|
@ApiModelProperty("高频开关电源柜温度")
|
@TableField("acdcm_temp")
|
private Float acdcmTemp;
|
|
@ApiModelProperty("模块1输出电压")
|
@TableField("m1_out_vol")
|
private Float m1OutVol;
|
|
@TableField("m2_out_vol")
|
private Float m2OutVol;
|
|
@TableField("m3_out_vol")
|
private Float m3OutVol;
|
|
@TableField("m4_out_vol")
|
private Float m4OutVol;
|
|
@TableField("m5_out_vol")
|
private Float m5OutVol;
|
|
@TableField("m6_out_vol")
|
private Float m6OutVol;
|
|
@TableField("m7_out_vol")
|
private Float m7OutVol;
|
|
@TableField("m8_out_vol")
|
private Float m8OutVol;
|
|
@TableField("m9_out_vol")
|
private Float m9OutVol;
|
|
@TableField("m10_out_vol")
|
private Float m10OutVol;
|
|
@TableField("m11_out_vol")
|
private Float m11OutVol;
|
|
@TableField("m12_out_vol")
|
private Float m12OutVol;
|
|
@TableField("m13_out_vol")
|
private Float m13OutVol;
|
|
@TableField("m14_out_vol")
|
private Float m14OutVol;
|
|
@TableField("m15_out_vol")
|
private Float m15OutVol;
|
|
@TableField("m16_out_vol")
|
private Float m16OutVol;
|
|
|
@TableField("is_acb1_over_curr_a")
|
private Integer isAcb1OverCurrA;
|
|
@TableField("is_acb1_over_curr_b")
|
private Integer isAcb1OverCurrB;
|
|
@TableField("is_acb1_over_curr_c")
|
private Integer isAcb1OverCurrC;
|
|
@TableField("is_ac_in1_poweron")
|
private Integer isAcIn1Poweron;
|
|
@TableField("is_ac_in2_poweron")
|
private Integer isAcIn2Poweron;
|
|
@TableField("is_dc_out_over_curr")
|
private Integer isDcOutOverCurr;
|
|
@TableField("is_battgroup1_state")
|
private Integer isBattgroup1State;
|
|
@TableField("is_battgroup2_state")
|
private Integer isBattgroup2State;
|
|
@TableField("is_battgroup2_down")
|
private Integer isBattgroup2Down;
|
|
@TableField("is_battgroup1_overchgcurr")
|
private Integer isBattgroup1Overchgcurr;
|
|
@TableField("is_battgroup2_overchgcurr")
|
private Integer isBattgroup2Overchgcurr;
|
|
@TableField("is_acdc_mod1_overvol")
|
private Integer isAcdcMod1Overvol;
|
|
@TableField("is_acdc_mod1_undervol")
|
private Integer isAcdcMod1Undervol;
|
|
@TableField("is_acdc_mod1_overcurr")
|
private Integer isAcdcMod1Overcurr;
|
|
@TableField("is_acdc_mod1_acerr")
|
private Integer isAcdcMod1Acerr;
|
|
@TableField("is_acdc_mod1_limitcurr")
|
private Integer isAcdcMod1Limitcurr;
|
|
|
@TableField("is_acdc_mod2_overvol")
|
private Integer isAcdcMod2Overvol;
|
|
@TableField("is_acdc_mod2_undervol")
|
private Integer isAcdcMod2Undervol;
|
|
@TableField("is_acdc_mod2_overcurr")
|
private Integer isAcdcMod2Overcurr;
|
|
@TableField("is_acdc_mod2_acerr")
|
private Integer isAcdcMod2Acerr;
|
|
@TableField("is_acdc_mod2_limitcurr")
|
private Integer isAcdcMod2Limitcurr;
|
|
@TableField("is_acdc_mod3_overvol")
|
private Integer isAcdcMod3Overvol;
|
|
@TableField("is_acdc_mod3_undervol")
|
private Integer isAcdcMod3Undervol;
|
|
@TableField("is_acdc_mod3_overcurr")
|
private Integer isAcdcMod3Overcurr;
|
|
@TableField("is_acdc_mod3_acerr")
|
private Integer isAcdcMod3Acerr;
|
|
@TableField("is_acdc_mod3_limitcurr")
|
private Integer isAcdcMod3Limitcurr;
|
|
@TableField("is_acdc_mod4_overvol")
|
private Integer isAcdcMod4Overvol;
|
|
@TableField("is_acdc_mod4_undervol")
|
private Integer isAcdcMod4Undervol;
|
|
@TableField("is_acdc_mod4_overcurr")
|
private Integer isAcdcMod4Overcurr;
|
|
@TableField("is_acdc_mod4_acerr")
|
private Integer isAcdcMod4Acerr;
|
|
@TableField("is_acdc_mod4_limitcurr")
|
private Integer isAcdcMod4Limitcurr;
|
|
@TableField("is_acdc_mod5_overvol")
|
private Integer isAcdcMod5Overvol;
|
|
@TableField("is_acdc_mod5_undervol")
|
private Integer isAcdcMod5Undervol;
|
|
@TableField("is_acdc_mod5_overcurr")
|
private Integer isAcdcMod5Overcurr;
|
|
@TableField("is_acdc_mod5_acerr")
|
private Integer isAcdcMod5Acerr;
|
|
@TableField("is_acdc_mod5_limitcurr")
|
private Integer isAcdcMod5Limitcurr;
|
|
@TableField("is_acdc_mod6_overvol")
|
private Integer isAcdcMod6Overvol;
|
|
@TableField("is_acdc_mod6_undervol")
|
private Integer isAcdcMod6Undervol;
|
|
@TableField("is_acdc_mod6_overcurr")
|
private Integer isAcdcMod6Overcurr;
|
|
@TableField("is_acdc_mod6_acerr")
|
private Integer isAcdcMod6Acerr;
|
|
@TableField("is_acdc_mod6_limitcurr")
|
private Integer isAcdcMod6Limitcurr;
|
|
@TableField("is_acdc_mod7_overvol")
|
private Integer isAcdcMod7Overvol;
|
|
@TableField("is_acdc_mod7_undervol")
|
private Integer isAcdcMod7Undervol;
|
|
@TableField("is_acdc_mod7_overcurr")
|
private Integer isAcdcMod7Overcurr;
|
|
@TableField("is_acdc_mod7_acerr")
|
private Integer isAcdcMod7Acerr;
|
|
@TableField("is_acdc_mod7_limitcurr")
|
private Integer isAcdcMod7Limitcurr;
|
|
@TableField("is_acdc_mod8_overvol")
|
private Integer isAcdcMod8Overvol;
|
|
@TableField("is_acdc_mod8_undervol")
|
private Integer isAcdcMod8Undervol;
|
|
@TableField("is_acdc_mod8_overcurr")
|
private Integer isAcdcMod8Overcurr;
|
|
@TableField("is_acdc_mod8_acerr")
|
private Integer isAcdcMod8Acerr;
|
|
@TableField("is_acdc_mod8_limitcurr")
|
private Integer isAcdcMod8Limitcurr;
|
|
@TableField("is_acdc_mod9_overvol")
|
private Integer isAcdcMod9Overvol;
|
|
@TableField("is_acdc_mod9_undervol")
|
private Integer isAcdcMod9Undervol;
|
|
@TableField("is_acdc_mod9_overcurr")
|
private Integer isAcdcMod9Overcurr;
|
|
@TableField("is_acdc_mod9_acerr")
|
private Integer isAcdcMod9Acerr;
|
|
@TableField("is_acdc_mod9_limitcurr")
|
private Integer isAcdcMod9Limitcurr;
|
|
@TableField("is_acdc_mod10_overvol")
|
private Integer isAcdcMod10Overvol;
|
|
@TableField("is_acdc_mod10_undervol")
|
private Integer isAcdcMod10Undervol;
|
|
@TableField("is_acdc_mod10_overcurr")
|
private Integer isAcdcMod10Overcurr;
|
|
@TableField("is_acdc_mod10_acerr")
|
private Integer isAcdcMod10Acerr;
|
|
@TableField("is_acdc_mod10_limitcurr")
|
private Integer isAcdcMod10Limitcurr;
|
|
@TableField("is_acdc_mod11_overvol")
|
private Integer isAcdcMod11Overvol;
|
|
@TableField("is_acdc_mod11_undervol")
|
private Integer isAcdcMod11Undervol;
|
|
@TableField("is_acdc_mod11_overcurr")
|
private Integer isAcdcMod11Overcurr;
|
|
@TableField("is_acdc_mod11_acerr")
|
private Integer isAcdcMod11Acerr;
|
|
@TableField("is_acdc_mod11_limitcurr")
|
private Integer isAcdcMod11Limitcurr;
|
|
@TableField("is_acdc_mod12_overvol")
|
private Integer isAcdcMod12Overvol;
|
|
@TableField("is_acdc_mod12_undervol")
|
private Integer isAcdcMod12Undervol;
|
|
@TableField("is_acdc_mod12_overcurr")
|
private Integer isAcdcMod12Overcurr;
|
|
@TableField("is_acdc_mod12_acerr")
|
private Integer isAcdcMod12Acerr;
|
|
@TableField("is_acdc_mod12_limitcurr")
|
private Integer isAcdcMod12Limitcurr;
|
|
@TableField("is_acdc_mod13_overvol")
|
private Integer isAcdcMod13Overvol;
|
|
@TableField("is_acdc_mod13_undervol")
|
private Integer isAcdcMod13Undervol;
|
|
@TableField("is_acdc_mod13_overcurr")
|
private Integer isAcdcMod13Overcurr;
|
|
@TableField("is_acdc_mod13_acerr")
|
private Integer isAcdcMod13Acerr;
|
|
@TableField("is_acdc_mod13_limitcurr")
|
private Integer isAcdcMod13Limitcurr;
|
|
@TableField("is_acdc_mod14_overvol")
|
private Integer isAcdcMod14Overvol;
|
|
@TableField("is_acdc_mod14_undervol")
|
private Integer isAcdcMod14Undervol;
|
|
@TableField("is_acdc_mod14_overcurr")
|
private Integer isAcdcMod14Overcurr;
|
|
@TableField("is_acdc_mod14_acerr")
|
private Integer isAcdcMod14Acerr;
|
|
@TableField("is_acdc_mod14_limitcurr")
|
private Integer isAcdcMod14Limitcurr;
|
|
@TableField("is_acdc_mod15_overvol")
|
private Integer isAcdcMod15Overvol;
|
|
@TableField("is_acdc_mod15_undervol")
|
private Integer isAcdcMod15Undervol;
|
|
@TableField("is_acdc_mod15_overcurr")
|
private Integer isAcdcMod15Overcurr;
|
|
@TableField("is_acdc_mod15_acerr")
|
private Integer isAcdcMod15Acerr;
|
|
@TableField("is_acdc_mod15_limitcurr")
|
private Integer isAcdcMod15Limitcurr;
|
|
@TableField("is_acdc_mod16_overvol")
|
private Integer isAcdcMod16Overvol;
|
|
@TableField("is_acdc_mod16_undervol")
|
private Integer isAcdcMod16Undervol;
|
|
@TableField("is_acdc_mod16_overcurr")
|
private Integer isAcdcMod16Overcurr;
|
|
@TableField("is_acdc_mod16_acerr")
|
private Integer isAcdcMod16Acerr;
|
|
@TableField("is_acdc_mod16_limitcurr")
|
private Integer isAcdcMod16Limitcurr;
|
|
|
@TableField("is_ac_in1_fuse")
|
private Integer isAcIn1Fuse;
|
|
@TableField("is_ac_in2_fuse")
|
private Integer isAcIn2Fuse;
|
|
@TableField("is_ac_in1_unbanlance")
|
private Integer isAcIn1Unbanlance;
|
|
@TableField("is_ac_in2_unbanlance")
|
private Integer isAcIn2Unbanlance;
|
|
@TableField("is_ac_in1_freqerr")
|
private Integer isAcIn1Freqerr;
|
|
@TableField("is_ac_in2_freqerr")
|
private Integer isAcIn2Freqerr;
|
|
@TableField("is_battgroup1_vollow")
|
private Integer isBattgroup1Vollow;
|
|
@TableField("is_battgroup2_volLow")
|
private Integer isBattgroup2Vollow;
|
|
@TableField("is_dc_out_total_alarm")
|
private Integer isDcOutTotalAlarm;
|
|
@TableField("is_ac_in_total_alarm")
|
private Integer isAcInTotalAlarm;
|
|
@TableField("is_acdc_mod1_junchg")
|
private Integer isAcdcMod1Junchg;
|
|
@TableField("is_acdc_mod2_junchg")
|
private Integer isAcdcMod2Junchg;
|
|
@TableField("is_acdc_mod3_junchg")
|
private Integer isAcdcMod3Junchg;
|
|
|
@TableField("is_acdc_mod4_junchg")
|
private Integer isAcdcMod4Junchg;
|
|
|
@TableField("is_acdc_mod5_junchg")
|
private Integer isAcdcMod5Junchg;
|
|
|
@TableField("is_acdc_mod6_junchg")
|
private Integer isAcdcMod6Junchg;
|
|
|
@TableField("is_acdc_mod7_junchg")
|
private Integer isAcdcMod7Junchg;
|
|
|
@TableField("is_acdc_mod8_junchg")
|
private Integer isAcdcMod8Junchg;
|
|
|
@TableField("is_acdc_mod9_junchg")
|
private Integer isAcdcMod9Junchg;
|
|
|
@TableField("is_acdc_mod10_junchg")
|
private Integer isAcdcMod10Junchg;
|
|
|
@TableField("is_acdc_mod11_junchg")
|
private Integer isAcdcMod11Junchg;
|
|
|
@TableField("is_acdc_mod12_junchg")
|
private Integer isAcdcMod12Junchg;
|
|
|
@TableField("is_acdc_mod13_junchg")
|
private Integer isAcdcMod13Junchg;
|
|
|
@TableField("is_acdc_mod14_junchg")
|
private Integer isAcdcMod14Junchg;
|
|
|
@TableField("is_acdc_mod15_junchg")
|
private Integer isAcdcMod15Junchg;
|
|
|
@TableField("is_acdc_mod16_junchg")
|
private Integer isAcdcMod16Junchg;
|
|
@TableField("is_powerdev_commerr")
|
private Integer isPowerdevCommerr;
|
|
@TableField("userac_in1_vol_a")
|
private Float useracIn1VolA;
|
|
@TableField("userac_in1_vol_b")
|
private Float useracIn1VolB;
|
|
@TableField("userac_in1_vol_b")
|
private Float useracIn1VolC;
|
|
@TableField("userac_in1_curr_a")
|
private Float useracIn1CurrA;
|
|
@TableField("userac_in1_curr_b")
|
private Float useracIn1CurrB;
|
|
@TableField("userac_in1_curr_c")
|
private Float useracIn1CurrC;
|
|
@TableField("userac_in1_freq")
|
private Float useracIn1Freq;
|
|
@TableField("userac_in2_vol_a")
|
private Float useracIn2VolA;
|
|
@TableField("userac_in2_vol_b")
|
private Float useracIn2VolB;
|
|
@TableField("userac_in2_vol_b")
|
private Float useracIn2VolC;
|
|
@TableField("userac_in2_curr_a")
|
private Float useracIn2CurrA;
|
|
@TableField("userac_in2_curr_b")
|
private Float useracIn2CurrB;
|
|
@TableField("userac_in2_curr_c")
|
private Float useracIn2CurrC;
|
|
@TableField("userac_in2_freq")
|
private Float useracIn2Freq;
|
|
@TableField("m_temper1")
|
private Float mTemper1;
|
|
@TableField("m_temper2")
|
private Float mTemper2;
|
|
@TableField("m_temper3")
|
private Float mTemper3;
|
|
@TableField("m_humidity1")
|
private Float mHumidity1;
|
|
@TableField("m_humidity2")
|
private Float mHumidity2;
|
|
@TableField("m_humidity3")
|
private Float mHumidity3;
|
|
@TableField("userac_in1_powerdown")
|
private Integer useracIn1Powerdown;
|
|
@TableField("userac_in1_commerr")
|
private Integer useracin1Commerr;
|
|
@TableField("userac_in2_powerdown")
|
private Integer useracIn2Powerdown;
|
|
@TableField("userAcIn2_CommErr")
|
private Integer useracin2Commerr;
|
|
@TableField("is_temp_commerr1")
|
private Integer isTempCommerr1;
|
|
@TableField("is_temp_commerr2")
|
private Integer isTempCommerr2;
|
|
@TableField("is_temp_commerr3")
|
private Integer isTempCommerr3;
|
|
@TableField("is_humi_commerr1")
|
private Integer isHumiCommerr1;
|
|
@TableField("is_humi_commerr2")
|
private Integer isHumiCommerr2;
|
|
@TableField("is_humi_commerr3")
|
private Integer isHumiCommerr3;
|
|
@TableField("is_smoke_alarm1")
|
private Integer isSmokeAlarm1;
|
|
@TableField("is_smoke_commerr1")
|
private Integer isSmokeCommerr1;
|
|
@TableField("is_smoke_alarm2")
|
private Integer isSmokeAlarm2;
|
|
@TableField("is_smoke_commerr2")
|
private Integer isSmokeCommerr2;
|
|
@TableField("is_smoke_alarm3")
|
private Integer isSmokeAlarm3;
|
|
@TableField("is_smoke_commerr3")
|
private Integer isSmokeCommerr3;
|
|
@TableField("ac_in2_curr_a")
|
private Integer acIn2CurrA;
|
|
@TableField("ac_in2_curr_b")
|
private Integer acIn2CurrB;
|
|
@TableField("ac_in2_curr_c")
|
private Integer acIn2CurrC;
|
|
@ApiModelProperty("交流输入1分合闸状态:0---未知(用于兼容以前的),1-分闸,2-合闸,3-脱扣")
|
@TableField("ac_in1_switch_st")
|
private Integer acIn1SwitchSt;
|
|
@ApiModelProperty("交流输入2分合闸状态 :0---未知(用于兼容以前的),1-分闸,2-合闸,3-脱扣")
|
@TableField("ac_in2_switch_st")
|
private Integer acIn2SwitchSt;
|
|
@TableField("charglimitcurr")
|
private float chargLimitCurr;
|
|
@TableField("junchargevol")
|
private float junChargeVol;
|
|
@TableField("floatchargevol")
|
private float floatChargeVol;
|
|
@TableField("acvolh_limit")
|
private float acVolhLimit;
|
|
@TableField("acvoll_limit")
|
private float acVollLimit;
|
|
@TableField("dc_outvolh_limit")
|
private float dcOutVolhLimit;
|
|
@TableField("dc_outvoll_limit")
|
private float dcOutVollLimit;
|
|
@TableField("ac_inusecount")
|
private int acInUseCount;
|
|
|
@TableField("m17_out_curr")
|
private Float m17OutCurr;
|
|
@TableField("is_acdc_mod17_err")
|
private Integer isAcdcMod17Err;
|
|
@TableField("is_acdc_mod17_off")
|
private Integer isAcdcMod17Off;
|
|
@TableField("m18_out_curr")
|
private Float m18OutCurr;
|
|
@TableField("is_acdc_mod18_err")
|
private Integer isAcdcMod18Err;
|
|
@TableField("is_acdc_mod18_off")
|
private Integer isAcdcMod18Off;
|
|
@TableField("m19_out_curr")
|
private Float m19OutCurr;
|
|
@TableField("is_acdc_mod19_err")
|
private Integer isAcdcMod19Err;
|
|
@TableField("is_acdc_mod19_off")
|
private Integer isAcdcMod19Off;
|
|
@TableField("m20_out_curr")
|
private Float m20OutCurr;
|
|
@TableField("is_acdc_mod20_err")
|
private Integer isAcdcMod20Err;
|
|
@TableField("is_acdc_mod20_off")
|
private Integer isAcdcMod20Off;
|
}
|