whycxzp
2025-04-14 8e85ad8e022d2885c410d0654bce08e2a392b08f
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
/*
package com.whyc.pojo;
 
import com.baomidou.mybatisplus.annotation.IdType;
import com.baomidou.mybatisplus.annotation.TableField;
import com.baomidou.mybatisplus.annotation.TableId;
import com.baomidou.mybatisplus.annotation.TableName;
import com.fasterxml.jackson.annotation.JsonFormat;
import io.swagger.annotations.ApiModel;
import io.swagger.annotations.ApiModelProperty;
import lombok.Data;
import lombok.EqualsAndHashCode;
import lombok.experimental.Accessors;
 
import java.io.Serializable;
import java.util.Date;
 
 
@Data
@EqualsAndHashCode(callSuper = false)
@Accessors(chain = true)
@TableName(schema = "db_power",value ="pwrdev_acdcdata")
@ApiModel(value="电源实时数据", description="")
public class PwrdevAcdcdata implements Serializable {
 
    private static final long serialVersionUID = 1L;
 
    @TableId(value = "num", type = IdType.AUTO)
    private int num;
 
    @TableField("pinf_id")
    private int pinfId;
 
    @JsonFormat(pattern="yyyy-MM-dd HH:mm:ss")
    private Date recordTime;
 
    @ApiModelProperty("第1路交流A相输入电压")
    @TableField("ac_in1_vol_a")
    private Float acIn1VolA;
    @ApiModelProperty("第1路交流B相输入电压")
    @TableField("ac_in1_vol_b")
    private Float acIn1VolB;
    @ApiModelProperty("第1路交流C相输入电压")
    @TableField("ac_in1_vol_c")
    private Float acIn1VolC;
    @ApiModelProperty("第2路交流A相输入电压")
    @TableField("ac_in2_vol_a")
    private Float acIn2VolA;
    @ApiModelProperty("第2路交流B相输入电压")
    @TableField("ac_in2_vol_b")
    private Float acIn2VolB;
    @ApiModelProperty("第2路交流C相输入电压")
    @TableField("ac_in2_vol_c")
    private Float acIn2VolC;
    @ApiModelProperty("交流A相输出电压")
    @TableField("ac_out_vol_a")
    private Float acOutVolA;
    @ApiModelProperty("交流B相输出电压")
    @TableField("ac_out_vol_b")
    private Float acOutVolB;
    @ApiModelProperty("交流C相输出电压")
    @TableField("ac_out_vol_c")
    private Float acOutVolC;
    @ApiModelProperty("交流A相输出电流")
    @TableField("ac_out_curr_a")
    private Float acOutCurrA;
    @ApiModelProperty("交流B相输出电流")
    @TableField("ac_out_curr_b")
    private Float acOutCurrB;
    @ApiModelProperty("交流C相输出电流")
    @TableField("ac_out_curr_c")
    private Float acOutCurrC;
    @ApiModelProperty("直流输出电压")
    @TableField("dc_out_vol")
    private Float dcOutVol;
    @ApiModelProperty("直流输出电流")
    @TableField("dc_out_curr")
    private Float dcOutCurr;
 
    @ApiModelProperty("蓄电池组1充电电压")
    @TableField("battgroup1_vol")
    private Float battgroup1Vol;
 
    @ApiModelProperty("蓄电池组1充电电流")
    @TableField("battgroup1_curr")
    private Float battgroup1Curr;
 
    @ApiModelProperty("蓄电池组2充电电压")
    @TableField("battgroup2_vol")
    private Float battgroup2Vol;
 
    @ApiModelProperty("蓄电池组1充电电流")
    @TableField("battgroup2_curr")
    private Float battgroup2Curr;
 
    @ApiModelProperty("交流配电柜温度")
    @TableField("temprature")
    private Float temprature;
 
    @ApiModelProperty("模块输出电压")
    @TableField("m_outputvol")
    private Float mOutputvol;
 
    @TableField("m1_out_curr")
    private Float m1OutCurr;
 
    @TableField("m2_out_curr")
    private Float m2OutCurr;
 
    @TableField("m3_out_curr")
    private Float m3OutCurr;
 
    @TableField("m4_out_curr")
    private Float m4OutCurr;
 
    @TableField("m5_out_curr")
    private Float m51OutCurr;
 
    @TableField("m6_out_curr")
    private Float m6OutCurr;
 
    @TableField("m7_out_curr")
    private Float m7OutCurr;
 
    @TableField("m8_out_curr")
    private Float m8OutCurr;
 
    @TableField("m9_out_curr")
    private Float m9OutCurr;
 
    @TableField("m10_out_curr")
    private Float m10OutCurr;
 
    @TableField("m11_out_curr")
    private Float m11OutCurr;
 
    @TableField("m12_outCurr")
    private Float m12OutCurr;
 
    @TableField("m13_out_curr")
    private Float m13OutCurr;
 
    @TableField("m14_out_curr")
    private Float m14OutCurr;
 
    @TableField("m15_out_curr")
    private Float m15OutCurr;
 
    @TableField("m16_out_curr")
    private Float m16OutCurr;
 
    @TableField("is_ac_in1_over_vol_a")
    private Integer isAcIn1OverVolA;
 
    @TableField("is_ac_in1_under_vol_a")
    private Integer isAcIn1UnderVolA;
 
    @TableField("is_ac_in1_less_a")
    private Integer isAcIn1LessA;
 
    @TableField("is_ac_in1_over_vol_b")
    private Integer isAcIn1OverVolB;
 
    @TableField("is_ac_in1_under_vol_b")
    private Integer isAcIn1UnderVolB;
 
    @TableField("is_ac_in1_less_b")
    private Integer isAcIn1LessB;
 
    @TableField("is_ac_in1_over_vol_c")
    private Integer isAcIn1OverVolC;
 
    @TableField("is_ac_in1_under_vol_c")
    private Integer isAcIn1UnderVolC;
 
    @TableField("is_ac_in1_less_c")
    private Integer isAcIn1LessC;
 
    @TableField("is_ac_in1_thunder_err")
    private Integer isAcIn1ThunderErr;
    @ApiModelProperty("交流输入1停电")
    @TableField("is_ac_in1_powerdown")
    private Integer isAcIn1Powerdown;
    @ApiModelProperty("第2路交流A相过压")
    @TableField("is_ac_in2_over_vol_a")
    private Integer isAcIn2OverVolA;
    @ApiModelProperty("第2路交流A相欠压")
    @TableField("is_ac_in2_under_vol_a")
    private Integer isAcIn2UnderVolA;
    @ApiModelProperty("第2路交流A相缺相")
    @TableField("is_ac_in2_less_a")
    private Integer isAcIn2LessA;
 
    @TableField("is_ac_in2_over_vol_b")
    private Integer isAcIn2OverVolB;
 
    @TableField("is_ac_in2_under_vol_b")
    private Integer isAcIn2UnderVolB;
 
    @TableField("is_ac_in2_less_b")
    private Integer isAcIn2LessB;
 
    @TableField("is_ac_in2_over_vol_c")
    private Integer isAcIn2OverVolC;
 
    @TableField("is_ac_in2_under_vol_c")
    private Integer isAcIn2UnderVolC;
 
    @TableField("is_ac_in2_less_c")
    private Integer isAcIn2LessC;
    @ApiModelProperty("交流输入2防雷器故障")
    @TableField("is_ac_in2_thunder_err")
    private Integer isAcIn2ThunderErr;
 
    @TableField("is_ac_in2_powerdown")
    private Integer isAcIn2Powerdown;
    @ApiModelProperty("监控单元故障")
    @TableField("is_ac_in_monitorerr")
    private Integer isAcInMonitorerr;
    @ApiModelProperty("直流输出过压")
    @TableField("is_dc_out_over_vol")
    private Integer isDcOutOverVol;
    @ApiModelProperty("直流输出欠压")
    @TableField("is_dc_out_under_vol")
    private Integer isDcOutUnderVol;
    @ApiModelProperty("电池组下电保护告警")
    @TableField("is_battgroup_down")
    private Integer isBattgroupDown;
    @ApiModelProperty("均/浮充状态")
    @TableField("is_jun_charge")
    private Integer isJunCharge;
 
 
    @ApiModelProperty("模块1故障")
    @TableField("is_acdc_mod1_err")
    private Integer isAcdcMod1Err;
    @ApiModelProperty("模块1开/关机")
    @TableField("is_acdc_mod1_off")
    private Integer isAcdcMod1Off;
 
    @ApiModelProperty("模块2故障")
    @TableField("is_acdc_mod2_err")
    private Integer isAcdcMod2Err;
    @ApiModelProperty("模块2开/关机")
    @TableField("is_acdc_mod2_off")
    private Integer isAcdcMod2Off;
 
    @ApiModelProperty("模块3故障")
    @TableField("is_acdc_mod3_err")
    private Integer isAcdcMod3Err;
    @ApiModelProperty("模块3开/关机")
    @TableField("is_acdc_mod3_off")
    private Integer isAcdcMod3Off;
 
    @ApiModelProperty("模块4故障")
    @TableField("is_acdc_mod4_err")
    private Integer isAcdcMod4Err;
    @ApiModelProperty("模块4开/关机")
    @TableField("is_acdc_mod4_off")
    private Integer isAcdcMod4Off;
 
    @ApiModelProperty("模块5故障")
    @TableField("is_acdc_mod5_err")
    private Integer isAcdcMod5Err;
    @ApiModelProperty("模块5开/关机")
    @TableField("is_acdc_mod5_off")
    private Integer isAcdcMod5Off;
 
    @ApiModelProperty("模块6故障")
    @TableField("is_acdc_mod6_err")
    private Integer isAcdcMod6Err;
    @ApiModelProperty("模块6开/关机")
    @TableField("is_acdc_mod6_off")
    private Integer isAcdcMod6Off;
 
    @ApiModelProperty("模块7故障")
    @TableField("is_acdc_mod7_err")
    private Integer isAcdcMod7Err;
    @ApiModelProperty("模块7开/关机")
    @TableField("is_acdc_mod7_off")
    private Integer isAcdcMod7Off;
 
    @ApiModelProperty("模块8故障")
    @TableField("is_acdc_mod8_err")
    private Integer isAcdcMod8Err;
    @ApiModelProperty("模块8开/关机")
    @TableField("is_acdc_mod8_off")
    private Integer isAcdcMod8Off;
 
    @ApiModelProperty("模块9故障")
    @TableField("is_acdc_mod9_err")
    private Integer isAcdcMod9Err;
    @ApiModelProperty("模块9开/关机")
    @TableField("is_acdc_mod9_off")
    private Integer isAcdcMod9Off;
 
    @ApiModelProperty("模块10故障")
    @TableField("is_acdc_mod10_err")
    private Integer isAcdcMod10Err;
    @ApiModelProperty("模块10开/关机")
    @TableField("is_acdc_mod10_off")
    private Integer isAcdcMod10Off;
 
    @ApiModelProperty("模块11故障")
    @TableField("is_acdc_mod11_err")
    private Integer isAcdcMod11Err;
    @ApiModelProperty("模块11开/关机")
    @TableField("is_acdc_mod11_off")
    private Integer isAcdcMod11Off;
 
    @ApiModelProperty("模块12故障")
    @TableField("is_acdc_mod12_err")
    private Integer isAcdcMod12Err;
    @ApiModelProperty("模块12开/关机")
    @TableField("is_acdc_mod12_off")
    private Integer isAcdcMod12Off;
 
    @ApiModelProperty("模块13故障")
    @TableField("is_acdc_mod13_err")
    private Integer isAcdcMod13Err;
    @ApiModelProperty("模块13开/关机")
    @TableField("is_acdc_mod13_off")
    private Integer isAcdcMod13Off;
 
    @ApiModelProperty("模块14故障")
    @TableField("is_acdc_mod14_err")
    private Integer isAcdcMod14Err;
    @ApiModelProperty("模块14开/关机")
    @TableField("is_acdc_mod14_off")
    private Integer isAcdcMod14Off;
 
    @ApiModelProperty("模块15故障")
    @TableField("is_acdc_mod15_err")
    private Integer isAcdcMod15Err;
    @ApiModelProperty("模块15开/关机")
    @TableField("is_acdc_mod15_off")
    private Integer isAcdcMod15Off;
 
    @ApiModelProperty("模块16故障")
    @TableField("is_acdc_mod16_err")
    private Integer isAcdcMod16Err;
    @ApiModelProperty("模块16开/关机")
    @TableField("is_acdc_mod16_off")
    private Integer isAcdcMod16Off;
 
    @TableField("is_ac_in1_trip")
    private Integer isAcIn1Trip;
    @ApiModelProperty("第2路交流输入开关跳闸")
    @TableField("is_ac_in2_trip")
    private Integer isAcIn2Trip;
    @ApiModelProperty("负载熔丝状态")
    @TableField("is_loader_fuse")
    private Integer isLoaderFuse;
 
    @ApiModelProperty("电池组1熔丝告警")
    @TableField("is_battgroup1_fuse")
    private Integer isBattgroup1Fuse;
    @ApiModelProperty("电池组2熔丝告警")
    @TableField("is_battgroup2_fuse")
    private Integer isBattgroup2Fuse;
    @ApiModelProperty("高频开关电源柜总告警")
    @TableField("is_total_alarm")
    private Integer isTotalAlarm;
 
    @ApiModelProperty("第1路交流A相输入电流")
    @TableField("ac_in1_curr_a")
    private Float acIn1CurrA;
 
    @TableField("ac_in1_curr_b")
    private Float acIn1CurrB;
 
    @TableField("ac_in1_curr_c")
    private Float acIn1CurrC;
 
    @ApiModelProperty("负载电流")
    @TableField("loader_curr")
    private Float loaderCurr;
 
    @TableField("battgroup1_ah")
    private Float battgroup1Ah;
 
    @TableField("battgroup1_temp")
    private Float battgroup1Temp;
 
    @TableField("battgroup2_ah")
    private Float battgroup2Ah;
 
    @TableField("battgroup2_temp")
    private Float battgroup2Temp;
 
    @ApiModelProperty("高频开关电源柜温度")
    @TableField("acdcm_temp")
    private Float acdcmTemp;
 
    @ApiModelProperty("模块1输出电压")
    @TableField("m1_out_vol")
    private Float m1OutVol;
 
    @TableField("m2_out_vol")
    private Float m2OutVol;
 
    @TableField("m3_out_vol")
    private Float m3OutVol;
 
    @TableField("m4_out_vol")
    private Float m4OutVol;
 
    @TableField("m5_out_vol")
    private Float m5OutVol;
 
    @TableField("m6_out_vol")
    private Float m6OutVol;
 
    @TableField("m7_out_vol")
    private Float m7OutVol;
 
    @TableField("m8_out_vol")
    private Float m8OutVol;
 
    @TableField("m9_out_vol")
    private Float m9OutVol;
 
    @TableField("m10_out_vol")
    private Float m10OutVol;
 
    @TableField("m11_out_vol")
    private Float m11OutVol;
 
    @TableField("m12_out_vol")
    private Float m12OutVol;
 
    @TableField("m13_out_vol")
    private Float m13OutVol;
 
    @TableField("m14_out_vol")
    private Float m14OutVol;
 
    @TableField("m15_out_vol")
    private Float m15OutVol;
 
    @TableField("m16_out_vol")
    private Float m16OutVol;
 
 
    @TableField("is_acb1_over_curr_a")
    private Integer isAcb1OverCurrA;
 
    @TableField("is_acb1_over_curr_b")
    private Integer isAcb1OverCurrB;
 
    @TableField("is_acb1_over_curr_c")
    private Integer isAcb1OverCurrC;
 
    @TableField("is_ac_in1_poweron")
    private Integer isAcIn1Poweron;
 
    @TableField("is_ac_in2_poweron")
    private Integer isAcIn2Poweron;
 
    @TableField("is_dc_out_over_curr")
    private Integer isDcOutOverCurr;
 
    @TableField("is_battgroup1_state")
    private Integer isBattgroup1State;
 
    @TableField("is_battgroup2_state")
    private Integer isBattgroup2State;
 
    @TableField("is_battgroup2_down")
    private Integer isBattgroup2Down;
 
    @TableField("is_battgroup1_overchgcurr")
    private Integer isBattgroup1Overchgcurr;
 
    @TableField("is_battgroup2_overchgcurr")
    private Integer isBattgroup2Overchgcurr;
 
    @TableField("is_acdc_mod1_overvol")
    private Integer isAcdcMod1Overvol;
 
    @TableField("is_acdc_mod1_undervol")
    private Integer isAcdcMod1Undervol;
 
    @TableField("is_acdc_mod1_overcurr")
    private Integer isAcdcMod1Overcurr;
 
    @TableField("is_acdc_mod1_acerr")
    private Integer isAcdcMod1Acerr;
 
    @TableField("is_acdc_mod1_limitcurr")
    private Integer isAcdcMod1Limitcurr;
 
 
    @TableField("is_acdc_mod2_overvol")
    private Integer isAcdcMod2Overvol;
 
    @TableField("is_acdc_mod2_undervol")
    private Integer isAcdcMod2Undervol;
 
    @TableField("is_acdc_mod2_overcurr")
    private Integer isAcdcMod2Overcurr;
 
    @TableField("is_acdc_mod2_acerr")
    private Integer isAcdcMod2Acerr;
 
    @TableField("is_acdc_mod2_limitcurr")
    private Integer isAcdcMod2Limitcurr;
 
    @TableField("is_acdc_mod3_overvol")
    private Integer isAcdcMod3Overvol;
 
    @TableField("is_acdc_mod3_undervol")
    private Integer isAcdcMod3Undervol;
 
    @TableField("is_acdc_mod3_overcurr")
    private Integer isAcdcMod3Overcurr;
 
    @TableField("is_acdc_mod3_acerr")
    private Integer isAcdcMod3Acerr;
 
    @TableField("is_acdc_mod3_limitcurr")
    private Integer isAcdcMod3Limitcurr;
 
    @TableField("is_acdc_mod4_overvol")
    private Integer isAcdcMod4Overvol;
 
    @TableField("is_acdc_mod4_undervol")
    private Integer isAcdcMod4Undervol;
 
    @TableField("is_acdc_mod4_overcurr")
    private Integer isAcdcMod4Overcurr;
 
    @TableField("is_acdc_mod4_acerr")
    private Integer isAcdcMod4Acerr;
 
    @TableField("is_acdc_mod4_limitcurr")
    private Integer isAcdcMod4Limitcurr;
 
    @TableField("is_acdc_mod5_overvol")
    private Integer isAcdcMod5Overvol;
 
    @TableField("is_acdc_mod5_undervol")
    private Integer isAcdcMod5Undervol;
 
    @TableField("is_acdc_mod5_overcurr")
    private Integer isAcdcMod5Overcurr;
 
    @TableField("is_acdc_mod5_acerr")
    private Integer isAcdcMod5Acerr;
 
    @TableField("is_acdc_mod5_limitcurr")
    private Integer isAcdcMod5Limitcurr;
 
    @TableField("is_acdc_mod6_overvol")
    private Integer isAcdcMod6Overvol;
 
    @TableField("is_acdc_mod6_undervol")
    private Integer isAcdcMod6Undervol;
 
    @TableField("is_acdc_mod6_overcurr")
    private Integer isAcdcMod6Overcurr;
 
    @TableField("is_acdc_mod6_acerr")
    private Integer isAcdcMod6Acerr;
 
    @TableField("is_acdc_mod6_limitcurr")
    private Integer isAcdcMod6Limitcurr;
 
    @TableField("is_acdc_mod7_overvol")
    private Integer isAcdcMod7Overvol;
 
    @TableField("is_acdc_mod7_undervol")
    private Integer isAcdcMod7Undervol;
 
    @TableField("is_acdc_mod7_overcurr")
    private Integer isAcdcMod7Overcurr;
 
    @TableField("is_acdc_mod7_acerr")
    private Integer isAcdcMod7Acerr;
 
    @TableField("is_acdc_mod7_limitcurr")
    private Integer isAcdcMod7Limitcurr;
 
    @TableField("is_acdc_mod8_overvol")
    private Integer isAcdcMod8Overvol;
 
    @TableField("is_acdc_mod8_undervol")
    private Integer isAcdcMod8Undervol;
 
    @TableField("is_acdc_mod8_overcurr")
    private Integer isAcdcMod8Overcurr;
 
    @TableField("is_acdc_mod8_acerr")
    private Integer isAcdcMod8Acerr;
 
    @TableField("is_acdc_mod8_limitcurr")
    private Integer isAcdcMod8Limitcurr;
 
    @TableField("is_acdc_mod9_overvol")
    private Integer isAcdcMod9Overvol;
 
    @TableField("is_acdc_mod9_undervol")
    private Integer isAcdcMod9Undervol;
 
    @TableField("is_acdc_mod9_overcurr")
    private Integer isAcdcMod9Overcurr;
 
    @TableField("is_acdc_mod9_acerr")
    private Integer isAcdcMod9Acerr;
 
    @TableField("is_acdc_mod9_limitcurr")
    private Integer isAcdcMod9Limitcurr;
 
    @TableField("is_acdc_mod10_overvol")
    private Integer isAcdcMod10Overvol;
 
    @TableField("is_acdc_mod10_undervol")
    private Integer isAcdcMod10Undervol;
 
    @TableField("is_acdc_mod10_overcurr")
    private Integer isAcdcMod10Overcurr;
 
    @TableField("is_acdc_mod10_acerr")
    private Integer isAcdcMod10Acerr;
 
    @TableField("is_acdc_mod10_limitcurr")
    private Integer isAcdcMod10Limitcurr;
 
    @TableField("is_acdc_mod11_overvol")
    private Integer isAcdcMod11Overvol;
 
    @TableField("is_acdc_mod11_undervol")
    private Integer isAcdcMod11Undervol;
 
    @TableField("is_acdc_mod11_overcurr")
    private Integer isAcdcMod11Overcurr;
 
    @TableField("is_acdc_mod11_acerr")
    private Integer isAcdcMod11Acerr;
 
    @TableField("is_acdc_mod11_limitcurr")
    private Integer isAcdcMod11Limitcurr;
 
    @TableField("is_acdc_mod12_overvol")
    private Integer isAcdcMod12Overvol;
 
    @TableField("is_acdc_mod12_undervol")
    private Integer isAcdcMod12Undervol;
 
    @TableField("is_acdc_mod12_overcurr")
    private Integer isAcdcMod12Overcurr;
 
    @TableField("is_acdc_mod12_acerr")
    private Integer isAcdcMod12Acerr;
 
    @TableField("is_acdc_mod12_limitcurr")
    private Integer isAcdcMod12Limitcurr;
 
    @TableField("is_acdc_mod13_overvol")
    private Integer isAcdcMod13Overvol;
 
    @TableField("is_acdc_mod13_undervol")
    private Integer isAcdcMod13Undervol;
 
    @TableField("is_acdc_mod13_overcurr")
    private Integer isAcdcMod13Overcurr;
 
    @TableField("is_acdc_mod13_acerr")
    private Integer isAcdcMod13Acerr;
 
    @TableField("is_acdc_mod13_limitcurr")
    private Integer isAcdcMod13Limitcurr;
 
    @TableField("is_acdc_mod14_overvol")
    private Integer isAcdcMod14Overvol;
 
    @TableField("is_acdc_mod14_undervol")
    private Integer isAcdcMod14Undervol;
 
    @TableField("is_acdc_mod14_overcurr")
    private Integer isAcdcMod14Overcurr;
 
    @TableField("is_acdc_mod14_acerr")
    private Integer isAcdcMod14Acerr;
 
    @TableField("is_acdc_mod14_limitcurr")
    private Integer isAcdcMod14Limitcurr;
 
    @TableField("is_acdc_mod15_overvol")
    private Integer isAcdcMod15Overvol;
 
    @TableField("is_acdc_mod15_undervol")
    private Integer isAcdcMod15Undervol;
 
    @TableField("is_acdc_mod15_overcurr")
    private Integer isAcdcMod15Overcurr;
 
    @TableField("is_acdc_mod15_acerr")
    private Integer isAcdcMod15Acerr;
 
    @TableField("is_acdc_mod15_limitcurr")
    private Integer isAcdcMod15Limitcurr;
 
    @TableField("is_acdc_mod16_overvol")
    private Integer isAcdcMod16Overvol;
 
    @TableField("is_acdc_mod16_undervol")
    private Integer isAcdcMod16Undervol;
 
    @TableField("is_acdc_mod16_overcurr")
    private Integer isAcdcMod16Overcurr;
 
    @TableField("is_acdc_mod16_acerr")
    private Integer isAcdcMod16Acerr;
 
    @TableField("is_acdc_mod16_limitcurr")
    private Integer isAcdcMod16Limitcurr;
 
 
    @TableField("is_ac_in1_fuse")
    private Integer isAcIn1Fuse;
 
    @TableField("is_ac_in2_fuse")
    private Integer isAcIn2Fuse;
 
    @TableField("is_ac_in1_unbanlance")
    private Integer isAcIn1Unbanlance;
 
    @TableField("is_ac_in2_unbanlance")
    private Integer isAcIn2Unbanlance;
 
    @TableField("is_ac_in1_freqerr")
    private Integer isAcIn1Freqerr;
 
    @TableField("is_ac_in2_freqerr")
    private Integer isAcIn2Freqerr;
 
    @TableField("is_battgroup1_vollow")
    private Integer isBattgroup1Vollow;
 
    @TableField("is_battgroup2_volLow")
    private Integer isBattgroup2Vollow;
 
    @TableField("is_dc_out_total_alarm")
    private Integer isDcOutTotalAlarm;
 
    @TableField("is_ac_in_total_alarm")
    private Integer isAcInTotalAlarm;
 
    @TableField("is_acdc_mod1_junchg")
    private Integer isAcdcMod1Junchg;
 
    @TableField("is_acdc_mod2_junchg")
    private Integer isAcdcMod2Junchg;
 
    @TableField("is_acdc_mod3_junchg")
    private Integer isAcdcMod3Junchg;
 
 
    @TableField("is_acdc_mod4_junchg")
    private Integer isAcdcMod4Junchg;
 
 
    @TableField("is_acdc_mod5_junchg")
    private Integer isAcdcMod5Junchg;
 
 
    @TableField("is_acdc_mod6_junchg")
    private Integer isAcdcMod6Junchg;
 
 
    @TableField("is_acdc_mod7_junchg")
    private Integer isAcdcMod7Junchg;
 
 
    @TableField("is_acdc_mod8_junchg")
    private Integer isAcdcMod8Junchg;
 
 
    @TableField("is_acdc_mod9_junchg")
    private Integer isAcdcMod9Junchg;
 
 
    @TableField("is_acdc_mod10_junchg")
    private Integer isAcdcMod10Junchg;
 
 
    @TableField("is_acdc_mod11_junchg")
    private Integer isAcdcMod11Junchg;
 
 
    @TableField("is_acdc_mod12_junchg")
    private Integer isAcdcMod12Junchg;
 
 
    @TableField("is_acdc_mod13_junchg")
    private Integer isAcdcMod13Junchg;
 
 
    @TableField("is_acdc_mod14_junchg")
    private Integer isAcdcMod14Junchg;
 
 
    @TableField("is_acdc_mod15_junchg")
    private Integer isAcdcMod15Junchg;
 
 
    @TableField("is_acdc_mod16_junchg")
    private Integer isAcdcMod16Junchg;
 
    @TableField("is_powerdev_commerr")
    private Integer isPowerdevCommerr;
 
    @TableField("userac_in1_vol_a")
    private Float useracIn1VolA;
 
    @TableField("userac_in1_vol_b")
    private Float useracIn1VolB;
 
    @TableField("userac_in1_vol_b")
    private Float useracIn1VolC;
 
    @TableField("userac_in1_curr_a")
    private Float useracIn1CurrA;
 
    @TableField("userac_in1_curr_b")
    private Float useracIn1CurrB;
 
    @TableField("userac_in1_curr_c")
    private Float useracIn1CurrC;
 
    @TableField("userac_in1_freq")
    private Float useracIn1Freq;
 
    @TableField("userac_in2_vol_a")
    private Float useracIn2VolA;
 
    @TableField("userac_in2_vol_b")
    private Float useracIn2VolB;
 
    @TableField("userac_in2_vol_b")
    private Float useracIn2VolC;
 
    @TableField("userac_in2_curr_a")
    private Float useracIn2CurrA;
 
    @TableField("userac_in2_curr_b")
    private Float useracIn2CurrB;
 
    @TableField("userac_in2_curr_c")
    private Float useracIn2CurrC;
 
    @TableField("userac_in2_freq")
    private Float useracIn2Freq;
 
    @TableField("m_temper1")
    private Float mTemper1;
 
    @TableField("m_temper2")
    private Float mTemper2;
 
    @TableField("m_temper3")
    private Float mTemper3;
 
    @TableField("m_humidity1")
    private Float mHumidity1;
 
    @TableField("m_humidity2")
    private Float mHumidity2;
 
    @TableField("m_humidity3")
    private Float mHumidity3;
 
    @TableField("userac_in1_powerdown")
    private Integer useracIn1Powerdown;
 
    @TableField("userac_in1_commerr")
    private Integer useracin1Commerr;
 
    @TableField("userac_in2_powerdown")
    private Integer useracIn2Powerdown;
 
    @TableField("userAcIn2_CommErr")
    private Integer useracin2Commerr;
 
    @TableField("is_temp_commerr1")
    private Integer isTempCommerr1;
 
    @TableField("is_temp_commerr2")
    private Integer isTempCommerr2;
 
    @TableField("is_temp_commerr3")
    private Integer isTempCommerr3;
 
    @TableField("is_humi_commerr1")
    private Integer isHumiCommerr1;
 
    @TableField("is_humi_commerr2")
    private Integer isHumiCommerr2;
 
    @TableField("is_humi_commerr3")
    private Integer isHumiCommerr3;
 
    @TableField("is_smoke_alarm1")
    private Integer isSmokeAlarm1;
 
    @TableField("is_smoke_commerr1")
    private Integer isSmokeCommerr1;
 
    @TableField("is_smoke_alarm2")
    private Integer isSmokeAlarm2;
 
    @TableField("is_smoke_commerr2")
    private Integer isSmokeCommerr2;
 
    @TableField("is_smoke_alarm3")
    private Integer isSmokeAlarm3;
 
    @TableField("is_smoke_commerr3")
    private Integer isSmokeCommerr3;
 
    @TableField("ac_in2_curr_a")
    private Integer acIn2CurrA;
 
    @TableField("ac_in2_curr_b")
    private Integer acIn2CurrB;
 
    @TableField("ac_in2_curr_c")
    private Integer acIn2CurrC;
 
    @ApiModelProperty("交流输入1分合闸状态:0---未知(用于兼容以前的),1-分闸,2-合闸,3-脱扣")
    @TableField("ac_in1_switch_st")
    private Integer acIn1SwitchSt;
 
    @ApiModelProperty("交流输入2分合闸状态 :0---未知(用于兼容以前的),1-分闸,2-合闸,3-脱扣")
    @TableField("ac_in2_switch_st")
    private Integer acIn2SwitchSt;
 
    @TableField("charglimitcurr")
    private float chargLimitCurr;
 
    @TableField("junchargevol")
    private float junChargeVol;
 
    @TableField("floatchargevol")
    private float floatChargeVol;
 
    @TableField("acvolh_limit")
    private float acVolhLimit;
 
    @TableField("acvoll_limit")
    private float acVollLimit;
 
    @TableField("dc_outvolh_limit")
    private float dcOutVolhLimit;
 
    @TableField("dc_outvoll_limit")
    private float dcOutVollLimit;
 
    @TableField("ac_inusecount")
    private int acInUseCount;
 
 
    @TableField("m17_out_curr")
    private Float m17OutCurr;
 
    @TableField("is_acdc_mod17_err")
    private Integer isAcdcMod17Err;
 
    @TableField("is_acdc_mod17_off")
    private Integer isAcdcMod17Off;
 
    @TableField("m18_out_curr")
    private Float m18OutCurr;
 
    @TableField("is_acdc_mod18_err")
    private Integer isAcdcMod18Err;
 
    @TableField("is_acdc_mod18_off")
    private Integer isAcdcMod18Off;
 
    @TableField("m19_out_curr")
    private Float m19OutCurr;
 
    @TableField("is_acdc_mod19_err")
    private Integer isAcdcMod19Err;
 
    @TableField("is_acdc_mod19_off")
    private Integer isAcdcMod19Off;
 
    @TableField("m20_out_curr")
    private Float m20OutCurr;
 
    @TableField("is_acdc_mod20_err")
    private Integer isAcdcMod20Err;
 
    @TableField("is_acdc_mod20_off")
    private Integer isAcdcMod20Off;
}
*/